欢迎访问ic37.com |
会员登录 免费注册
发布采购

DSEC29-02A 参数 Datasheet PDF下载

DSEC29-02A图片预览
型号: DSEC29-02A
PDF下载: 下载PDF文件 查看货源
内容描述: HiPerFRED外延二极管共阴极和软恢复 [HiPerFRED Epitaxial Diode with common cathode and soft recovery]
分类和应用: 二极管
文件页数/大小: 2 页 / 53 K
品牌: IXYS [ IXYS CORPORATION ]
 浏览型号DSEC29-02A的Datasheet PDF文件第2页  
DSEC 29-02A
DSEC 29-02AS
HiPerFRED
TM
Epitaxial Diode
with common cathode and soft recovery
I
FAV
= 2x15 A
V
RRM
= 200 V
t
rr
= 25 ns
TO-220 AC
A
C
A
V
RSM
V
200
200
V
RRM
V
200
200
Type
DSEC 29-02A
DSEC 29-02AS
C (TAB)
TO-263
A
A
C (TAB)
A = Anode, C = Cathode, TAB = Cathode
Symbol
I
FRMS
I
FAVM
I
FSM
E
AS
I
AR
T
VJ
T
VJM
T
stg
P
tot
M
d
Weight
Conditions
T
C
= 150°C; rectangular, d = 0.5
T
VJ
= 45°C; t
p
= 10 ms (50 Hz), sine
T
VJ
= 25°C; non-repetitive
I
AS
= 2.5 A; L = 180 µH
V
A
= 1.5·V
R
typ.; f = 10 kHz; repetitive
Maximum Ratings
35
15
140
0.8
0.3
-55...+175
175
-55...+150
A
A
A
mJ
A
°C
°C
°C
W
Nm
lb.in.
g
Features
International standard package
Planar passivated chips
Very short recovery time
Extremely low switching losses
Low I
RM
-values
Soft recovery behaviour
Epoxy meets UL 94V-0
Applications
• Antiparallel diode for high frequency
switching devices
• Antisaturation diode
• Snubber diode
• Free wheeling diode in converters
and motor control circuits
• Rectifiers in switch mode power
supplies (SMPS)
• Inductive heating
• Uninterruptible power supplies (UPS)
• Ultrasonic cleaners and welders
Advantages
• Avalanche voltage rated for reliable
operation
• Soft reverse recovery for low
EMI/RFI
• Low I
RM
reduces:
- Power dissipation within the diode
- Turn-on loss in the commutating switch
T
C
= 25°C
mounting torque
typical
95
0.45...0.55
4...5
2/4
Symbol
I
R
Conditions
T
VJ
= 25°C; V
R
= V
RRM
T
VJ
= 150°C; V
R
= V
RRM
I
F
= 15 A;
T
VJ
= 150°C
T
VJ
= 25°C
Characteristic Values
typ.
max.
100
0.5
0.86
1.06
1.6
0.5
µA
mA
V
V
K/W
K/W
ns
4.4
A
V
F
R
thJC
R
thCH
t
rr
I
RM
I
F
= 1 A; -di/dt = 100 A/µs;
V
R
= 30 V; T
VJ
= 25°C
V
R
= 100 V; I
F
= 25 A; -di
F
/dt = 100 A/µs
T
VJ
= 100°C
25
3.5
Dimensions see Outlines.pdf
Pulse test:
Pulse Width = 5 ms, Duty Cycle < 2.0 %
Pulse Width = 300
µs,
Duty Cycle < 2.0 %
Data according to IEC 60747 and per diode unless otherwise specified.
IXYS reserves the right to change limits, test conditions and dimensions.
© 2004 IXYS All rights reserved
1-2
432