欢迎访问ic37.com |
会员登录 免费注册
发布采购

DSEP60-06AT 参数 Datasheet PDF下载

DSEP60-06AT图片预览
型号: DSEP60-06AT
PDF下载: 下载PDF文件 查看货源
内容描述: HiPerFREDTM外延二极管具有软恢复 [HiPerFREDTM Epitaxial Diode with soft recovery]
分类和应用: 二极管
文件页数/大小: 2 页 / 43 K
品牌: IXYS [ IXYS CORPORATION ]
 浏览型号DSEP60-06AT的Datasheet PDF文件第2页  
DSEP 60-06A
DSEP 60-06AT
HiPerFRED
TM
Epitaxial Diode
with soft recovery
Preliminary Data
V
RSM
V
600
V
RRM
V
600
DSEP 60-06A
DSEP 60-06AT
Type
A
C
I
FAV
= 60 A
V
RRM
= 600 V
t
rr
= 35 ns
TO-247 AD
(A-Type)
TO-268 AA
(AT-Type)
C
A
C (TAB)
A
A
C (TAB)
A = Anode, C = Cathode, TAB = Cathode
Symbol
I
FRMS
I
FAVM
I
FSM
E
AS
I
AR
T
VJ
T
VJM
T
stg
P
tot
M
d
Weight
Conditions
T
VJ
= T
VJM
T
C
= 110°C; rectangular, d = 0.5
T
VJ
= 45°C; t
p
= 10 ms (50 Hz), sine
T
VJ
= 25°C; non-repetitive
I
AS
= 1.6 A; L = 180 µH
V
A
= 1.5·V
R
typ.; f = 10 kHz; repetitive
Maximum Ratings
70
60
600
0.3
0.2
-55...+175
175
-55...+150
A
A
Features
A
q
mJ
A
°C
°C
°C
W
Nm
g
q
q
q
q
q
q
International standard package
Planar passivated chips
Very short recovery time
Extremely low switching losses
Low I
RM
-values
Soft recovery behaviour
Epoxy meets UL 94V-0
T
C
= 25°C
mounting torque
typical
230
0.8...1.2
6
Applications
q
q
q
Symbol
I
R
x
Conditions
T
VJ
= 25°C V
R
= V
RRM
T
VJ
= 150°C V
R
= V
RRM
I
F
= 60 A;
T
VJ
= 150°C
T
VJ
= 25°C
Characteristic Values
typ.
max.
650
2.5
1.39
2.04
0.65
0.25
mA
mA
V
V
K/W
K/W
ns
q
q
q
q
q
V
F
y
R
thJC
R
thCH
t
rr
I
RM
Antiparallel diode for high frequency
switching devices
Antisaturation diode
Snubber diode
Free wheeling diode in converters
and motor control circuits
Rectifiers in switch mode power
supplies (SMPS)
Inductive heating
Uninterruptible power supplies (UPS)
Ultrasonic cleaners and welders
Advantages
q
I
F
= 1 A; -di/dt = 300 A/ms;
V
R
= 30 V; T
VJ
= 25°C
V
R
= 100 V; I
F
= 130 A; -di
F
/dt = 100 A/ms
T
VJ
= 100°C
35
8.3
A
q
q
Avalanche voltage rated for reliable
operation
Soft reverse recovery for low
EMI/RFI
Low I
RM
reduces:
- Power dissipation within the diode
- Turn-on loss in the commutating
switch
Pulse test:
x
Pulse Width = 5 ms, Duty Cycle < 2.0 %
y
Pulse Width = 300
ms,
Duty Cycle < 2.0 %
Data according to IEC 60747 and per diode unless otherwise specified
Dimensions see outlines.pdf
© 2000 IXYS All rights reserved
1-2
018
IXYS reserves the right to change limits, test conditions and dimensions.