欢迎访问ic37.com |
会员登录 免费注册
发布采购

VHF15-16IO5 参数 Datasheet PDF下载

VHF15-16IO5图片预览
型号: VHF15-16IO5
PDF下载: 下载PDF文件 查看货源
内容描述: 半控单相整流桥 [Half Controlled Single Phase Rectifier Bridge]
分类和应用:
文件页数/大小: 3 页 / 98 K
品牌: IXYS [ IXYS CORPORATION ]
 浏览型号VHF15-16IO5的Datasheet PDF文件第2页浏览型号VHF15-16IO5的Datasheet PDF文件第3页  
VHF 15
Half Controlled
Single Phase Rectifier Bridge
with Freewheeling Diode
I
dAVM
= 21 A
V
RRM
= 800-1600 V
V
RSM
V
DSM
V
900
1300
1500
1700
V
RRM
V
DRM
V
800
1200
1400
1600
Type
6
4
2
1
3
4
1
2
3
6
VHF 15-08io5
VHF 15-12io5
VHF 15-14io5
VHF 15-16io5
8
8
Symbol
I
dAV
I
dAVM
x
I
FRMS
, I
TRMS
I
FSM
, I
TSM
Test Conditions
T
K
= 85°C, module
module
per leg
T
VJ
= 45°C;
V
R
= 0 V
T
VJ
= T
VJM
V
R
= 0 V
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
repetitive, I
T
= 50 A
Maximum Ratings
15
21
15
190
210
170
190
160
180
140
145
150
A
A
A
A
A
A
A
A
2
s
A
2
s
A
2
s
A
2
s
A/ms
Features
Package with DCB ceramic base
plate
Isolation voltage 3600 V~
Planar passivated chips
1/4" fast-on terminals
UL registered E 72873
q
q
q
q
q
I
2
t
T
VJ
= 45°C
V
R
= 0 V
T
VJ
= T
VJM
V
R
= 0 V
Applications
Supply for DC power equipment
DC motor control
q
q
(di/dt)
cr
T
VJ
= 125°C
f =50 Hz, t
P
=200
ms
V
D
= 2/3 V
DRM
I
G
= 0.3 A,
di
G
/dt = 0.3 A/ms
q
q
q
non repetitive, I
T
= 1/2 • I
dAV
500
1000
10
A/ms
V/ms
Advantages
Easy to mount with two screws
Space and weight savings
Improved temperature and power
cycling
(dv/dt)
cr
V
RGM
P
GM
P
GAVM
T
VJ
T
VJM
T
stg
V
ISOL
M
d
Weight
T
VJ
= T
VJM
; V
DR
= 2/3 V
DRM
R
GK
=
¥;
method 1 (linear voltage rise)
T
VJ
= T
VJM
I
T
= I
TAVM
t
p
= 30
ms
t
p
= 500
ms
t
p
= 10 ms
£
£
£
Dimensions in mm (1 mm = 0.0394")
V
W
W
W
W
°C
°C
°C
V~
V~
Nm
lb.in.
g
10
5
1
0.5
-40...+125
125
-40...+125
50/60 Hz, RMS
I
ISOL
£
1 mA
Mounting torque
t = 1 min
t=1s
(M5)
(10-32 UNF)
3000
3600
2-2.5
18-22
50
Data according to IEC 60747 and refer to a single thyristor/diode unless otherwise stated.
x
for resistive load
IXYS reserves the right to change limits, test conditions and dimensions.
© 2000 IXYS All rights reserved
1-3