BENCHTOP/RACKMOUNT PROGRAMMABLE SWITCHES
4
SC and SCG Models Specifications
Parameter
1
Single Common
C Configuration
(SC model only)
Typical
Maximum
0.4 dB
-
0.4 dB
-
>
65 dB
Multiple Common
D Configuration
Typical
Maximum
Multiple Common
E and F Configurations
Typical
Maximum
IL
SM
SC with 3 and 4 inputs and SCG models
MM
SC with 3 and 4 inputs and SCG models
RL
2
SM standard/analog
MM
4
standard/analog
PDL SM
IL stability
5
Repeatability
7
Sequential switching
Random switching
Crosstalk (maximum) SM
Maximum input power (optical)
Lifetime
Switching time
One channel (SCG model)
Each additional channel (SCG model)
Power supply
Power consumption
Control
Drivers for external switch modules
Operation temperature
Storage temperature
Humidity
Dimensions (W x H x D) single (double height
6
)
Weight single (double height
6
)
25/35 dB
0.02 dB
± 0.03 dB
± 0.003 dB
± 0.01 dB
60/65 dB
20/30 dB
0.05 dB
± 0.05 dB
± 0.005 dB
± 0.025 dB
>
65 dB
0.7 dB
-
0.7 dB
-
0.4 dB
0.5 dB
0.4 dB
0.5 dB
0.7 dB
1.0 dB
0.7 dB
1.0 dB
60/65 dB
3
20/30 dB
3
0.05 dB
± 0.05 dB
0.5 dB
0.7 dB
0.5 dB
0.7 dB
>
65 dB
1.0 dB
1.5 dB
1.0 dB
1.5 dB
60 dB
20 dB
0.07 dB
± 0.05 dB
± 0.01 dB
± 0.04 dB
25/35 dB
0.02 dB
± 0.03 dB
3
> 25 dB
0.03 dB
± 0.03 dB
± 0.005 dB
± 0.01 dB
± 0.005 dB
± 0.02 dB
± 0.04 dB
± 0.02 dB
-80 dB
300 mW
> 80 million cycles (> 10 million cycles on SCG)
300 ms (420 ms)
12 ms (20 ms)
100 to 240 V, 50 to 60 Hz
100 V A maximum
Local and remote via GPIB and serial RS-232 interfaces
Four open collector drivers with maximum 100 mA sink current
0 to 55 °C
-40 to 70 °C
Maximum 95 % RH from 0 to 55 °C non-condensing
48 x 13 x 37 cm (48 x 26.6 x 37 cm) excluding handles
9 kg (14 kg)
1. Excluding connectors. All optical measurements taken after temperature has been stabilized for one hour, at ambient (room) conditions.
2. RL specification based on 1 m pigtail length.
3. Analog version available on one and two input SC model switches (C and D configurations).
4. Values shown for 62.5 µm diameter maximum fiber core.
5. Drift of any channel relative to reference channel at ± 3 °C deviation of ambient temperature over a seven-day period.
6. Applies to SC model only.
7. Measured between two consecutive readings over 100 cycles.