SS-226 R3  
9-3 Endurance Characteristics  
Item  
Requirement  
Conditions  
Solderability  
A new coating of solder shall cover a  
Flux: 25 wt% colophony  
minimum of 95% of the surface being immersed  
Solder: H60A (Silver 3%)  
Preheating: 150°C for 1 min  
Soldering Temperature: 230 5°C  
Soldering Temperature: 215 5°C (MC1005)  
Immersion Time: 3 1 sec  
Resistance to  
Soldering Heat  
Flax: 25 wt% colophony  
Solder: H60A (Silver 3%)  
Soldering Temperature: 270 5°C  
Immersion Time: 10 1 sec  
Resistance  
to Humidity  
(Load Test)  
Temperature: 60 2°C  
Relative Humidity: 95% RH  
Test Voltage: Rated Voltage  
Test Hours: 1000 -0/+48 hours  
Visual Examination: No mechanical damage  
Capacitance: Within 2.0% or 0.02 pF  
whichever is more  
Q Value: 100 or more  
Insulation Resistance: 10,000 Mor more  
Resistance  
to Humidity  
(Unload Test)  
Temperature: 85 2°C  
Relative Humidity: 85% RH  
Test Hours: 1000 -0/+48 hours  
Resistance to  
Temperature: 125 2°C  
High Temperature  
Test Voltage: Rated Voltage  
Test Hours: 1000 -0/+48 hours  
Resistance to  
Low Heat  
Temperature: -55 2°C  
Test Hours: 1000 -0/+48 hours  
Temperature  
Cycle  
Temperature: -55°C 30 min 125°C 30 min  
Hours for 1 Cycle: 2 hours  
Temperature Cycle: 50 cycles or more  
Visual Examination: No mechanical damage  
Capacitance: Within 2.0% or 0.02 pF  
whichever is more  
Q Value: 100 or more  
Insulation Resistance: 10,000 Mor more  
Vibration  
Shock  
Frequency of Vibration: 10 to 100 Hz  
Sweeping: 1010010Hz 5 min 5.0 G  
This motion shall be applied for a period of  
2 hrs in each of 3 mutually perpendicular axes  
Half of sine wave (100 G) shall be applied  
for a period of 5 msec. in each of 3 mutually  
perpendicular axes  
The specimen shall be subjected to standard atmospheric condition for 24 hours  
after which measurement shall be made.  