KK78LXX
RECOMMENDED OPERATING CONDITIONS
78Lxx
IL78L05
IL78L06
IL78L08
IL78L09
Input voltage, VI
IL78L10
IL78L12
IL78L15
IL78L18
IL78L24
Output current, Io
Operating virtual junction temperature, Tj
-40
Min.
7
8
10.5
11.5
12.5
14.5
17.5
20.5
26.5
Max.
20
20
23
24
25
27
30
33
39
100
125
㎃
℃
V
Unit
TYPICAL APPLICATION
Notes
1. To specify an output voltage, substitute voltage for "XX"
2. Bypass capacitors are recommended for optimum stability and transient response
and should be located as close as possible to the regulators.