ZWS-SERIES
Single output 5W ~ 300W
Ⅵ Model name
ZWS 10-5/
Output Wattage
ZWS300
Output Voltage
Series Name
Option
blank: Molex connector, PCB type
A: Molex connector, with-cover type
J: JST connector, PCB type
JA: JST connector, with-cover type
ZWS50
ZWS 300-5/
Output Wattage
Output Voltage
Series Name
Option
ZWS30
R: With Remote ON/OFF control
T: Vertical terminal type
B: Input/Output connector terminal type
(Only for 12V-48V output type)
ZWS15
Ⅵ Features
ZWS10
ⅷ
marking (Low Voltage Directive)
ⅷWide input voltage range for 100V/200V, single output
ⅷ Low cost
ZWS5
ⅷ PCB type
ⅷ Applicable to various use;from office printer
to air conditioning controller
ⅷ Applicable to peak current load
(Low Voltage Directive)
2 year warranty
Ⅵ Specifications
1. Input voltage range
ZWS5
ZWS300
~
50
85
85
~
265VAC (47
~
440Hz) , 110
~
330VDC universal input
~132/170
~
265VAC (47
~440Hz) auto-selectable
2. Output Voltage range
3. Cooling
Convection cooling
4. Operating ambient
temperature
(Standard mounting)
ZWS5
ZWS300
~
50
-10°C~+50°C:100%,+60°C:70%
Convection cooling -10°C~+40°C:100%,+50°C:80%,+60°C:60%
Forced air cooling -10°C~+50°C:100%,+60°C:75%,+70°C:50%
Input-output : 3kVAC (20mA) , Input-chassis : 2kVAC (20mA) , Output-chassis : 500VAC (100mA) for 1 min
Approved by UL1950 , CSA950(C-UL) , EN60950(TUV)
5. Withstand voltage
6. Safety standard
7. CE marking
8. EMI
Conforms to low voltage directive
Meets to EN55011-B,EN55022-B,FCC-B,VCCI-B
Meets to EN50082-2(EN61000-4-2,-3,-4,-5,-6)
Over voltage protection,Over current protection
9. Immunity
10. Functions
Note 1
Note 1
Ⅵ Product lineup
Nominal
Max.
Max. peak
Max. output
Nominal
Max.
Max. peak
Max. output
Model name
UL CSA EN
Model name
UL CSA EN
output voltage output current output current power
output voltage output current output current power
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
ZWS5-3
ZWS5-5
3.3V
5V
1.0A
1.0A
0.42A
0.34A
0.22A
2.0A
2.0A
0.85A
0.7A
0.45A
3.0A
3.0A
1.25A
1.0A
0.65A
1.2A
1.2A
0.51A
0.41A
0.27A
2.4A
3.3W
5W
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
ZWS30-3
ZWS30-5
ZWS30-12
ZWS30-15
ZWS30-24
ZWS30-36
ZWS30-48
ZWS50-3
3.3V
5V
6.0A
6.0A
2.5A
2.0A
1.3A
0.9A
0.7A
10A
7.2A
7.2A
3.0A
19.8W
30W
30W
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
ZWS5
ZWS5-12
ZWS5-15
ZWS5-24
ZWS10-3
ZWS10-5
ZWS10-12
ZWS10-15
ZWS10-24
ZWS15-3
ZWS15-5
ZWS15-12
ZWS15-15
ZWS15-24
12V
15V
24V
3.3V
5V
12V
15V
24V
3.3V
5V
5.04W
5.1W
5.28W
6.6W
10W
10.2W
10.5W
10.8W
9.9W
15W
12V
15V
24V
36V
48V
3.3V
5V
12V
15V
24V
36V
48V
ZWS30
ZWS50
2.4A
30W
1.56A
1.08A
0.84A
12A
12A
5.16A
4.2A
2.52A
1.68A
1.32A
31.2W
32.4W
33.6W
33W
2.4A
ZWS10
ZWS15
1.02A
0.84A
0.54A
3.6A
3.6A
1.5A
ZWS50-5
10A
50W
ZWS50-12
ZWS50-15
ZWS50-24
ZWS50-36
ZWS50-48
4.3A
3.5A
2.1A
1.4A
1.1A
51.6W
52.5W
50.4W
50.4W
52.8W
12V
15V
24V
15W
15W
15.6W
1.2A
0.78A
⅜ : Safety standard approved
Note 1: Duration at peak current: 10 seconds max., Duty: Below 35%.
ⅷ Standard model: Molex connector
ⅷ “/J” model is available with J.S.T connector.
ZWS300 Series
Model name
ZWS300-3
Convection cooling
Forced air cooling
Safety standard
Nominal output voltage Maximum output current Maximum output power Max. peak output power Nominal output voltage Maximum output current Maximum output power
UL
CSA
⅜
EN
3.3V
5V
12V
15V
24V
48V
40A
40A
17A
14A
9A
132W
200W
204W
210W
216W
201.6W
198W
300W
324W
330W
336W
302.4W
3.3V
5V
12V
15V
24V
48V
60A
60A
27A
22A
14A
6.3A
198W
300W
324W
330W
336W
302.4W
⅜
⅜
⅜
⅜
⅜
⅜
⅜
ZWS300-5
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
⅜
ZWS300-12
ZWS300-15
ZWS300-24
ZWS300-48
4.2A
⅜
Note : Duration under peak application is limited less than 30 seconds.
ⅷ Request customer specification for further details of specifications, outline,
characteristics, etc. Read the instruction manual before usage.
ⅷ Contact us about delivery before ordering.
(Average output current under those condition should not exceed maximum output power.)
66