ABSOLUTE MAXIMUM RATINGS
Storage Temperature . . . . . . . . . . . . . .-65
°
C to +150
°
C
Ambient Temperature
with Power Applied . . . . . . . . . . . . . .-55
°
C to +125
°
C
Supply Voltage
with Respect to Ground . . . . . . . . . . -0.5 V to +7.0 V
DC Input Voltage . . . . . . . . . . . -0.5 V to V
CC
+ 0.5 V
DC Output or I/O
Pin Voltage . . . . . . . . . . . . . . . . . -0.5 V to V
CC
+ 0.5 V
Static Discharge Voltage . . . . . . . . . . . . . . . . . 2001 V
Latchup Current (T
A
= 0
°C
to 75°C) . . . . . . . . . 100 mA
Stresses above those listed under Absolute Maximum Ratings
may cause permanent device failure. Functionality at or above
these limits is not implied. Exposure to Absolute Maximum
Ratings for extended periods may affect device reliability.
Programming conditions may differ.
OPERATING RANGES
Commercial (C) Devices
Ambient Temperature (T
A
) Operating
in Free Air . . . . . . . . . . . . . . . . . . . . . . . 0°C to +75°C
Supply Voltage (V
CC
)
with Respect to Ground . . . . . . . . . +4.75 V to +5.25 V
Operating ranges define those limits between which the
functionality of the device is guaranteed.
DC CHARACTERISTICS OVER COMMERCIAL OPERATING RANGES
Parameter
Symbol
V
OH
V
OL
V
IH
V
IL
I
IH
I
IL
I
OZH
I
OZL
I
SC
I
CC
(Static)
I
CC
(Dynamic)
Parameter Description
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage
Input HIGH Leakage Current
Input LOW Leakage Current
Off-State Output Leakage Current HIGH
Off-State Output Leakage Current LOW
Output Short-Circuit Current
Supply Current for -5
Supply Current for -7 and -10
Test Description
I
OH
= -3.2 mA, V
IN
= V
IH
or V
IL
, V
CC
= Min
I
OL
= 24 mA, V
IN
= V
IH
or V
IL
, V
CC
= Min
Guaranteed Input Logical HIGH
Voltage for all Inputs (Note 1)
Guaranteed Input Logical LOW
Voltage for all Inputs (Note 1)
V
IN
= 5.25 V, V
CC
= Max (Note 2)
V
IN
= 0 V, V
CC
= Max (Note 2)
V
OUT
= 5.25 V, V
CC
= Max
V
IN
= V
IH
or V
IL
(Note 2)
V
OUT
= 0 V, V
CC
= Max
V
IN
= V
IH
or V
IL
(Note 2)
V
OUT
= 0.5 V, V
CC
= Max (Note 3)
Outputs Open (I
OUT
= 0 mA), V
IN
= 0 V
V
CC
= Max
Outputs Open (I
OUT
= 0 mA),
V
CC
= Max, f = 25 MHz
–30
2.0
0.8
10
–100
10
–100
–150
125
115
Min
2.4
0.5
Max
Unit
V
V
V
V
µA
µA
µA
µA
mA
mA
mA
Notes:
1. These are absolute values with respect to device ground, and all overshoots due to system or tester noise are included.
2. I/O pin leakage is the worst case of I
IL
and I
OZL
(or I
IH
and I
OZH
).
3. Not more than one output should be shorted at a time, and the duration of the short-circuit should not exceed one second.
V
OUT
= 0.5 V has been chosen to avoid test problems caused by tester ground degradation.
10