型号: AKR-B420L
PDF下载: 下载PDF文件 查看货源
内容描述: 交流电流变送器 [AC Current transducer]
分类和应用:
文件页数/大小: 2 页 / 219 K
品牌: LEM [ LEM ]
 浏览型号AKR-B420L的Datasheet PDF文件第2页  
AC Current transducer AKR-B420L
A Split Core transducer for the electronic measurement AC waveforms
current, with galvanic isolation between the primary (High power) and
the secondary circuits (Electronic circuit). Jumper selectable ranges
and True RMS 4-20mA current output.
I
PN
= 2..200A
Electrical data
Primary Nominal Current
I
PN
(A.t.RMS)
2,5
10,20,50
100,150,200
Vc
R
L
V
b
V
d
f
Analogue Output Signal
1)
I
OUT
(mA)
4-20
4-20
4-20
AKR 5 B420L
Type
RoHS
Date Code
JUNE 2006
Features
VFD and SCR waveforms current
measurement
True RMS responding
Split core box
Current output
Loop powered transducers
Panel mounting
Jumper selectable ranges
AKR 50 B420L
planned
AKR 200 B420L
planned
24
V DC
V AC
kV AC
Hz
Supply voltage (Loop powered)
Load resistance
see power supply diagram
Rated voltage (CAT III, PD2)
150
RMS Isolation voltage test, 50 Hz, 1mn
3
Frequency bandwith
10-400
Advantages
Large aperture
High isolation between primary and
secondary circuits
Easy to mount
Accuracy - Dynamic performance data
X
t
r
Accuracy @ I
PN
, T
A
=25°C
Response time @ 90% of I
PN
±
1
< 600
%
mS
Applications
VFD Controlled Loads: VFD output
indicates how the motor and
General data
T
A
T
S
m
Ambient operating temperature (0-95% RH)
Ambient storage temperature
Mass
Safety
EMC
- 20 ..+ 50
- 20 ..+ 85
120
IEC 61010-1
EN 61326
°C
°C
g
attached load are operating.
SCR Controlled Loads:
Acurate measurement of phase
angle fired or burst fired (time
proportioned) SCRs.
Switching Power Supplies and
Electronic Ballasts: True RMS sensing
Note:
1)
For 4-20mA output model, no saturation output up to 23 mA.
is the most accurate way to
measure power supply or ballast
input power.
Selecting the transducer
VFD (Variable Frequency Drive) and SCR (Semi Conductor Rectifier) output
waveforms are rough approximations of a sine wave. There are numerous spikes
and dips in each cycle. AKR transducers use a mathematical algorithm called
“True RMS,” which integrates the actual waveform over time. True RMS is the only
way to accurately measure distorted AC waveforms.
Select AKR transducers for
nonlinear loads or in “noisy” power environments.
Options on request
DIN mounting
060816/5
Page 1/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM
www .lem.com