欢迎访问ic37.com |
会员登录 免费注册
发布采购

AKR200C420L 参数 Datasheet PDF下载

AKR200C420L图片预览
型号: AKR200C420L
PDF下载: 下载PDF文件 查看货源
内容描述: 交流电流变送器 [AC Current transducer]
分类和应用:
文件页数/大小: 2 页 / 122 K
品牌: LEM [ LEM ]
 浏览型号AKR200C420L的Datasheet PDF文件第2页  
AC Current transducer AKR-C420L
Transducer for the electronic measurement AC waveforms current,
with galvanic isolation between the primary (High power) and the
secondary circuits (Electronic circuit). Jumper selectable ranges and
True RMS 4-20mA current output.
I
PN
= 2..200A
Electrical data
Primary Nominal CurrentAnalogue Output Signal
1)
I
PN
(A.t.RMS)
2,5
10,20,50
100,150,200
Vc
R
L
V
b
V
d
f
I
OUT
(mA)
4-20
4-20
4-20
AKR 5 C420L
AKR 50 C420L
AKR 200 C420L
24
Type
RoHS
Date Code
JULY 2006
planned
JULY 2006
V DC
VAC
kV AC
Hz
Features
VFD and SCR waveforms current
measurement
True RMS responding
4-20 mA Current output
Loop powered transducers
Panel mounting
Accurate
Jumper selectable ranges
Supply voltage (Loop powered)
Load resistance
see power supply diagram
Rated voltage (CAT III, PD2)
150
RMS Isolation voltage test, 50 Hz, 1mn
3
Frequency bandwith
20-100
Advantages
Large aperture
High isolation between primary and
secondary circuits
Accuracy - Dynamic performance data
X
t
r
Accuracy @ I
PN
, T
A
=25°C
Response time @ 90% of I
PN
±
1
< 600
%
mS
Easy to mount
Applications
VFD Controlled Loads:
VFD output indicates how the motor
and attached load are operating.
SCR Controlled Loads:
Acurate measurement of phase
angle fired or burst fired (time
proportioned) SCRs.
Switching Power Supplies and
Electronic Ballasts:
True RMS sensing is the most
accurate way to measure power
supply or ballast input power.
General data
T
A
T
S
m
Ambient operating temperature (0-95% RH)
Ambient storage temperature
Mass
Safety
EMC
1)
-20 ..+ 50
-20 ..+ 85
90
IEC 61010-1
EN 61326
°C
°C
g
Note:
For 4-20mA output model, no saturation output up to 23 mA.
Selecting the transducer
VFD (Variable Frequency Drive) and SCR (Semi Conductor Rectifier) output
waveforms are rough approximations of a sine wave. There are numerous spikes
and dips in each cycle. AKR transducers use a mathematical algorithm called
“True RMS,” which integrates the actual waveform over time. True RMS is the only
way to accurately measure distorted AC waveforms.
Select AKR transducers for
nonlinear loads or in “noisy” power environments.
Options on request
DIN mounting
060816/6
Page 1/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM
www .lem.com