AC Current transducer AP-B10
Split core transducer for the electronic measurement AC waveforms
current, with galvanic isolation between the primary (High power) and
the secondary circuits (Electronic circuit). Switch selectable ranges
and RMS 0-5V and 0-10V switch selectable voltage output.
I
PN
= 10 .. 400 A
Electrical data
Primary Nominal Current
I
PN
(A.t.RMS)
10,25,50
50,75,100
100,150,200
200,300,400
Analogue Output Signal
V
OUT
(V)
0-5V
0-5V
0-5V
0-5V
or
or
or
or
0-10V
0-10V
0-10V
0-10V
AP
AP
AP
AP
Type
50 B10
100 B10
200 B10
400 B10
Features
•
RMS output
•
Split core type
•
5V & 10V switch selectable voltage
output
•
DIN mounting & Panel mounting
•
Eliminates insertion loss
•
Switch selectable ranges
R
L
V
C
I
C
Load resistance
Supply voltage
Current Consumption
Limitation of voltage output (0-10V)
Limitation of voltage output (0-5V)
Overloaded input current
≥
10
kΩ
+24 ±5% V DC
< 30
mA
14
V
7
V
no limitation
Accuracy-Dynamic performance data
Advantages
< ±1
% of
I
PN
< ±0.5 % of
I
PN
< ±0.5 % of
I
PN
±1
mV/K
±0.1
%/K
< 150
ms
30 .. 2000 Hz
•
Large aperture for cable up to
Ø18mm
•
High isolation between primary and
secondary circuits
•
Easy to mount
ε
X
L
V
OE
V
OT
TC
ε
G
t
r
f
Accuracy @
I
PN
,
T
A
= 25°C (without offset)
Linearity (0 .. ±
I
PN
)
Electrical offset voltage,
T
A
= 25°C
Thermal drift of
V
OE
Thermal drift of the gain (% of reading)
Response time @ 90% of
I
P
Frequency bandwidth (±1%)
General data
T
A
T
S
m
dCp
dCl
CTI
Ambient operating temperature
Ambient storage temperature
Mass
Protection type
Creepage distance
Clearance distance
Comparative tracking index (Group I)
UL94 classification
-20 .. +60
°C
-20 .. +85
°C
90
g
IP20
5.5
mm
5.5
mm
600
V
V0
Applications
•
Automation systems
Analog current reading for remote
monitoring (e.g. motor) and
software alarms.
•
Panelmeters
Simple connection displays power
consumption.
Insulation category
V
b
Rated Voltage
300
with IEC 61010-1 standards and following conditions :
- Single insulation
- Over voltage category CAT III
- Pollution degree PD2
- None uniform field
R.m.s. voltage for AC insulation test, 50Hz, 1mn
5
R.m.s. voltage for partial discharge extinction @ 10pC 1.5
Peak impulse withstand voltage 1.2/50µs
6.1
If insulated cable is used for the primary circuit, the voltage category
could be improved with the following table :
Cable insulation (primary)
Category
HAR 05
600V CAT III
HAR 07
1000V CAT III
The operator must have accrediation to install this material.
The users must take care of all protection gurantee against electrical shock.
V
V
d
V
e
V
w
kV
kV
kV
Notes :
Installation and maintenance should be done with power supply disconnected.
.
041029/3
LEM Components
www.lem.com