Current Transducer LTS 6-NP
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
I
PN
=
6 At
Electrical data
I
PN
I
P
Î
PDC
V
OUT
N
S
R
L
R
IM
TCR
IM
V
C
I
C
Primary nominal r.m.s. current
Primary current, measuring range
Overload capability
Analog output voltage @
I
P
I
P
= 0
Number of secondary turns (± 0.1 %)
Load resistance
Internal measuring resistance (± 0.5 %)
Thermal drift of
R
IM
Supply voltage (± 5 %)
Current consumption @
V
C
= 5 V
6
At
0 .. ± 19.2
At
250
At
2.5
±
(0.625
·
I
P
/I
PN
) V
2.5
1)
V
2000
2
k
208.33
< 50
ppm/K
5
V
2)
28+
I
S
+ (V
OUT
/R
L
)mA
Features
Closed loop (compensated) multi-
range current transducer using the
Hall effect
Unipolar voltage supply
Compact design for PCB mounting
Insulated plastic case recognized
according to UL 94-V0
Incorporated measuring resistance
Extended measuring range.
Typ
Accuracy - Dynamic performance data
X
Advantages
± 0.2
± 0.7
< 0.1
Typ
80
%
%
%
Max
200 ppm/K
250 ppm/K
50
3)
ppm/K
± 0.5
mV
± 2.0
mV
± 2.0
mV
ns
ns
A/µs
kHz
kHz
ε
L
Accuracy @
I
PN
,
T
A
= 25°C
Accuracy with
R
IM
@
I
PN
,
T
A
= 25°C
Linearity error
- 10°C .. + 85°C
- 40°C .. - 10°C
Thermal drift of the gain
- 40°C .. + 85°C
Residual voltage @
I
P
= 0,after an overload of 3 x
I
PN
5 x
I
PN
10 x
I
PN
Reaction time @ 10 % of
I
PN
Response time @ 90 % of
I
PN
di/dt accurately followed
Frequency bandwidth (0 .. - 0.5 dB)
(- 0.5 .. 1 dB)
TCV
OUT
Thermal drift of
V
OUT
@
I
P
= 0
TC
ε
G
V
OM
Excellent accuracy
Very good linearity
Very low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
t
r a
t
r
di/dt
f
< 100
< 400
> 15
DC .. 100
DC .. 200
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding
applications.
General data
T
A
T
S
m
Ambient operating temperature
Ambient storage temperature
Insulating material group
Mass
Standards
4)
1)
2)
3)
4)
- 40 .. + 85
- 40 .. + 100
III a
10
EN 50178 : 1997
IEC 60950-1 : 2001
°C
°C
g
Application domain
Industrial.
Copyright protected.
Notes :
Absolute value @
T
A
= 25°C, 2.475 <
V
OUT
< 2.525
Please see the operation principle on the other side
Only due to
TCR
IM
Specification according to IEC 61000-4-3 are not guaranteed between
95 and 110 MHz (value higher by 5% than the specification).
050713/14
Page 1/3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM Components
Tope Co., Ltd.
Tel: (02) 8228-0658
Fax: (02) 8228-0659
http://www.sensor.com.tw
www.lem.com
e-mail: tope@ms1.hinet.net