Current Transducer FA-050 .. 100PV
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
I
PN
= 50 .. 100 A
Electrical data
Primary nominal
DC current
Primary current
measuring range
Type
I
PN
(A)
50
100
I
P
(A)
0 .. ± 70
0 .. ± 130
FA - 050PV
FA - 050PV
FA - 100PV
FA - 100PV
V
OUT
I
C
V
C
V
d
Output voltage
@ ±
I
PN
,
R
L
= 10 kΩ,
T
A
= 25°C ± 4
Current consumpution
16 +
I
PN
/1000
Features
V
mA
V
kV
±4
16+I
PN
/2000
± 15
2.5
Supply voltage (± 5 %)
R.m.s. voltage for AC isolation test, AC50/60Hz, 1 min
•
Hall effect measuring principle
•
PC Board Mount Type
•
Low power consumption
•
Extended measuring range (3 x
I
PN
)
•
Galvanic isolation between Primary
and Secondary circuit
•
Isolation voltage 2000V
Accuracy-Dynamic performance data
ε
X
L
V
OE
V
OH
V
OT
TC
ε
G
t
r
f
Accuracy @
T
A
= 25°C, @ ± 15V (± 5%)
Linearity (0 .. ±
I
PN
)
Electrical offset voltage,
T
A
= 25°C
Hysteresis offset voltage @
I
P
= 0,
after an excursion of 1 x
I
PN
Thermal drift of
V
OE
Thermal drift of the gain (% of reading)
Response time @ 90% of
I
P
Frequency bandwidth (- 1 dB)
< ± 1.5 @I
PN
< ± 0.25
± 0.016
< ± 0.012
< ± 0.04
< ± 0.1
<1
DC .. 100
%
%
V
V
mV/°C
%/°C
µs
kHz
Advantages
•
Easy Mounting
•
Small size and space saving
•
Only one design for wide current
ratings range
•
High immunity to external inteference
Applications
General data
T
A
T
S
m
Ambient operating temperature
Ambient storage temperature
Mass
- 10 .. + 70
- 15 .. + 80
25
°C
°C
g
•
DC motor drives
•
Switched Mode Power Supplies
(SMPS)
•
AC variable speed drives
•
Uninterruptible Power Supplies
(UPS)
•
Battery supplied applications
•
Power supplies for welding
applications.
010301/1
www.nanalem.co.jp