欢迎访问ic37.com |
会员登录 免费注册
发布采购

HAC500-S 参数 Datasheet PDF下载

HAC500-S图片预览
型号: HAC500-S
PDF下载: 下载PDF文件 查看货源
内容描述: 电流传感器 [Current Transducers]
分类和应用: 传感器
文件页数/大小: 3 页 / 816 K
品牌: LEM [ LEM ]
 浏览型号HAC500-S的Datasheet PDF文件第2页浏览型号HAC500-S的Datasheet PDF文件第3页  
Current Transducers HAC 100..800-S
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
I
PN
= 100 .. 800 A
Electrical data
Primary nominal
current rms
I
PN
(A)
100
200
300
400
500
600
800
Primary current
measuring range
I
PM
(A)
±
±
±
±
±
±
±
300
600
900
1200
1500
1800
1800
Type
RoHS since
date code
46256
46220
planned
46242
planned
46186
46219
Features
Hall effect measuring principle
Galvanic isolation between primary
and secondary circuit
Isolation voltage 2500 V
Low power consumption
Extended measuring range (3 x
I
PN
)
HAC
HAC
HAC
HAC
HAC
HAC
HAC
100-S
200-S
300-S
400-S
500-S
600-S
800-S
V
C
I
C
R
IS
V
OUT
R
OUT
R
L
± 15
< ± 18
HAC 400..800-S
< ± 25
Isolation resistance @ 500 VDC
> 1000
Output voltage (Analog) @ ±
I
PN
,
R
L
= 10 kΩ,
T
A
= 25°C ± 4
Output internal resistance
100
Load resistance
> 10
Supply voltage (± 5 %)
Current consumption
HAC 100..300-S
V
mA
mA
MΩ
V
kΩ
Advantages
Easy mounting
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
Accuracy - Dynamic performance data
ε
X
L
V
OE
V
OH
TCV
OE
TCV
OUT
t
r
BW
Accuracy @
I
PN
,
T
A
= 25°C (excluding offset)
Linearity error (0 .. ±
I
PN
)
Electrical offset voltage,
T
A
= 25°C
Hysteresis offset voltage @
I
P
= 0;
after an excursion of 1 x
I
PN
Temperature coefficient of
V
OE
Temperature coefficient of
V
OUT
(% of reading)
Response time to 90% of
I
PN
step
Frequency bandwidth (- 3 dB)
1)
< ± 1 % of
I
PN
< ± 1 % of
I
PN
< ± 30
mV
< ± 35
mV
<±1
mV/K
< ± 0.1
%/K
<7
µs
DC .. 50
kHz
Applications
AC variable speed drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
General data
T
A
T
S
m
Ambient operating temperature
Ambient storage temperature
Mass
- 10 .. + 80
- 15 .. + 85
70
°C
°C
g
Application domain
Industrial
1)
Note :
Derating is needed to avoid excessive core heating at high frequency.
Page 1/3
061114/7
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com