欢迎访问ic37.com |
会员登录 免费注册
发布采购

HAT1200-S 参数 Datasheet PDF下载

HAT1200-S图片预览
型号: HAT1200-S
PDF下载: 下载PDF文件 查看货源
内容描述: 电流传感器HAT 500 〜 1500 -S [Current Transducer HAT 500~1500-S]
分类和应用: 传感器
文件页数/大小: 2 页 / 228 K
品牌: LEM [ LEM ]
 浏览型号HAT1200-S的Datasheet PDF文件第2页  
Current Transducer HAT 500..1500 -
S
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
I
PN
= 500 .. 1500 A
V
OUT
= ± 4 V
Preliminary
Electrical data
Primary nominal
r.m.s. current
I
PN
(A)
500
800
1000
1200
1500
Primary current
measuring range
I
P
(A)
±
±
±
±
±
1500
2400
3000
3000
3000
Type
HAT
HAT
HAT
HAT
HAT
500-S
800-S
1000-S
1200-S
1500-S
Features
Hall effect measuring principle
Galvanic isolation between primary
and secondary circuit
Isolation voltage 3000 V
Low power consumption
Extended measuring range(3 x
I
PN
)
Insulated plastic case recognized
according to UL 94-V0
V
C
I
C
V
d
V
b
R
IS
V
OUT
R
OUT
R
L
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50/60Hz, 1mn
R.m.s. rated voltage, safe separation
Isolation resistance @ 500 VDC
Output voltage @ ±
I
PN
,
R
L
= 10 kΩ,
T
A
= 25°C
Output internal resistance
Load resistance
± 15
V
± 15
mA
3
kV
1)
500
V
> 1000
MΩ
± 4V± 40 mV
100
>1
kΩ
Accuracy-Dynamic performance data
Advantages
<±1
<±1
< ± 20
% of
I
PN
% of
I
PN
mV
ε
X
L
V
OE
V
OH
V
OT
TC
ε
G
t
r
f
Accuracy @
I
PN
,
T
A
= 25°C (without offset)
Linearity
2)
(0 .. ±
I
PN
)
Electrical offset voltage,
T
A
= 25°C
Hysteresis offset voltage @
I
P
= 0;
after an excursion of 1 x
I
PN
Thermal drift of
V
OE
Thermal drift of the gain (% of reading)
Response time @ 90% of
I
P
Frequency bandwidth (- 3 dB)
3)
Easy mounting
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
< ± 10
mV
<±1
mV/K
< ± 0.1
%/K
<5
µs
DC .. 50
kHz
Applications
DC motor drives
Switched Mode Power Supplies
General data
T
A
T
S
m
Ambient operating temperature
Ambient storage temperature
Mass
Standards
4)
- 10 .. + 80
- 15 .. + 85
app. 300
EN 50178
°C
°C
g
Notes :
Pollution class 2, overvoltage category III.
Linearity data exclude the electrical offset.
3)
Please refer to derating curves in the technical file to avoid excessive
core heating at high frequency.
4)
Please consult characterisation report for more technical details and
application advice.
1)
2)
(SMPS)
AC variable speed drives
Uninterruptible Power Supplies
(UPS)
Battery supplied applications
Power supplies for welding
applications
991201/4
LEM Components