Current Transducer HAT 200..1500-S
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
I
PN
= 200..1500 A
V
OUT
= ± 4 V
Electrical data
Primary nominal
r.m.s. current
I
PN
(A)
200
400
500
600
750
800
1000
1200
1500
Primary current
measuring range
4)
I
P
(A)
±
±
±
±
±
±
±
±
±
600
1200
1500
1800
2250
2400
3000
3000
3000
Type
HAT
HAT
HAT
HAT
HAT
HAT
HAT
HAT
HAT
200-S
400-S
500-S
600-S
750-S
800-S
1000-S
1200-S
1500-S
Features
Hall effect measuring principle
Galvanic isolation between primary
and secondary circuit
Isolation voltage 3000 V
Low power consumption
Extended measuring range(3 x
I
PN
)
Insulated plastic case recognized
according to UL 94-V0
V
C
I
C
R
IS
V
OUT
R
OUT
R
L
Supply voltage (± 5 %)
4)
Current consumption
Isolation resistance @ 500 VDC
Output voltage @ ±
I
PN
,
R
L
= 10 kΩ,
T
A
= 25°C
Output internal resistance
Load resistance
± 15
± 15
> 1000
±4
100
> 10
V
mA
MΩ
V
kΩ
Advantages
Easy mounting
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
Accuracy-Dynamic performance data
ε
X
L
V
OE
V
OH
V
OT
TC
ε
G
t
r
f
Accuracy @
I
PN
,
T
A
= 25°C (without offset)
Linearity error
1)
(0 .. ±
I
PN
)
Electrical offset voltage,
T
A
= 25°C
Hysteresis offset voltage @
I
P
= 0;
after an excursion of 1 x
I
PN
Thermal drift of
V
OE
Thermal drift of the gain (% of reading)
Response time @ 90% of
I
P
Frequency bandwidth
2)
(- 3 dB)
< ± 1 % of
I
PN
< ± 1 % of
I
PN
< ± 20
mV
< ± 10
mV
<±1
mV/K
< ± 0.1
%/K
<5
µs
DC .. 25
kHz
Applications
DC motor drives
Switched Mode Power Supplies
(SMPS)
AC variable speed drives
Uninterruptible Power Supplies
(UPS)
Battery supplied applications
Power supplies for welding
applications
General data
T
A
T
S
m
Ambient operating temperature
- 10 .. + 80
Ambient storage temperature
HAT 200-S, HAT 500..1500-S
- 15 .. + 85
HAT 400-S
- 25 .. + 85
Mass
300
UL94 classification
V0
°C
°C
°C
g
Notes :
1)
2)
Linearity data exclude the electrical offset.
Please refer to derating curves in the technical file to avoid excessive
core heating at high frequency.
3)
Please consult characterisation report for more technical details and
application advice.
4)
Operating at ±12V
Vc < ±15V will reduce the measuring range.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
051011/9
Page 1/3
LEM Industrial