欢迎访问ic37.com |
会员登录 免费注册
发布采购

HAX1000-S 参数 Datasheet PDF下载

HAX1000-S图片预览
型号: HAX1000-S
PDF下载: 下载PDF文件 查看货源
内容描述: 电流传感器HAX 500到2500 -S [Current Transducers HAX 500 to 2500-S]
分类和应用: 传感器
文件页数/大小: 2 页 / 142 K
品牌: LEM [ LEM ]
 浏览型号HAX1000-S的Datasheet PDF文件第2页  
Current Transducers HAX 500 to 2500-S
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
I
PN
= 500 .. 2500 A
±
4V
V
OUT
=
Electrical data
Primary nominal
r.m.s. current
I
PN
(A)
500
850
1000
1200
1500
2000
2500
Primary current
measuring range
I
P
(A)
±
±
±
±
±
±
±
1500
2550
3000
3600
4500
5500
5500
Type
HAX
HAX
HAX
HAX
HAX
HAX
HAX
500-S
850-S
1000-S
1200-S
1500-S
2000-S
2500-S
Features
Hall effect measuring principle
Galvanic isolation between primary
and secondary circuit
Isolation voltage 5000 V~
Low power consumption
Extended measuring range (3 x
I
PN
)
Package in PBT meets UL 94-V0
V
C
I
C
I
OC
V
d
V
b
R
IS
V
OUT
R
OUT
R
L
Supply voltage (± 5 %)
Current consumption
Overload capacity
R.m.s. voltage for AC isolation test, 60 Hz, 1 mn
R.m.s. rated voltage, safe separation
Isolation resistance @ 500 VDC
Output voltage @ ±
I
PN
,
R
L
= 10 kΩ,
T
A
= 25°C
Output internal resistance
approx.
Load resistance
± 15
± 15
30,000
5
500
1)
> 1000
± 4V ± 40
100
>1
V
mA
At
kV
V
MΩ
mV
kΩ
Advantages
Easy mounting
Small size and space savings
Only one design for wide current
ratings range
High immunity against external
interference
Accuracy - Dynamic performance data
X
ε
L
V
OE
V
OH
V
OT
TC
ε
G
t
r
di/dt
f
Accuracy @
I
PN
,
T
A
= 25°C (without offset)
Linearity
2)
(0 .. ±
I
PN
)
Electrical offset voltage,
T
A
= 25°C
Hysteresis offset voltage @
I
P
= 0;
after an excursion of 1 x
I
PN
Thermal drift of
V
OE
Thermal drift of the gain (% of reading)
Response time @ 90% of
I
P
di/dt accurately followed
Frequency bandwidth
3)
(- 3 dB)
<±1
%
< ± 1 % of
I
PN
< ± 20
mV
< ± 30
mV
<±1
mV/K
< ± 0.1
%/K
<5
µs
> 50
A/µs
DC .. 25
kHz
Applications
AC motor speed control
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Power supplies for welding, cable TV
and telecommunication applications.
General data
T
A
T
S
m
Ambient operating temperature
Ambient storage temperature
Mass
Min. internal creepage distance/clearance
Isolation material group
Standards
4)
1)
2)
3)
- 25 .. + 85 °C
- 25 .. + 85 °C
approx. 450
g
8.5
mm
IIIa
EN 50178
Notes :
4)
Pollution class 2, overvoltage category III
Linearity data exclude the electrical offset.
Please refer to derating curves in the technical file to avoid excessive
core heating at high frequency
Please consult characterisation report for more technical details and
application advice.
031219/7
LEM Components
www.lem.com