欢迎访问ic37.com |
会员登录 免费注册
发布采购

HAZ12000-SB 参数 Datasheet PDF下载

HAZ12000-SB图片预览
型号: HAZ12000-SB
PDF下载: 下载PDF文件 查看货源
内容描述: 电流传感器 [Current Transducers]
分类和应用: 传感器
文件页数/大小: 3 页 / 855 K
品牌: LEM [ LEM ]
 浏览型号HAZ12000-SB的Datasheet PDF文件第2页浏览型号HAZ12000-SB的Datasheet PDF文件第3页  
Current Transducers HAZ 4000..20000-SB
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
I
PN
= 4000..20000 A
V
OUT
= ± 10 V
Electrical data
Primary nominal
DC current or AC peak
I
PN
(A)
4000
6000
10000
12000
14000
20000
Primary current
measuring range
I
PM
(A)
±
±
±
±
±
±
4000
6000
10000
12000
14000
20000
Type
RoHS since
date code
Features
HAZ
HAZ
HAZ
HAZ
HAZ
HAZ
4000-SB
6000-SB
10000-SB
12000-SB
14000-SB
20000-SB
46177
46177
46177
planned
planned
planned
Hall effect measuring principle
Galvanic isolation between primary
and secondary circuit
Instantaneous voltage output
Isolation voltage 12kV Rms /50 Hz
/1min
Low power consumption
Package in PBT meeting UL 94-V0
Instantaneous voltage output
V
C
I
C
Î
P
R
IS
V
OUT
R
OUT
R
L
Supply voltage (± 5 %)
± 15
Current consumption
± 30
Overload capability
30,000
Isolation resistance @ 500 VDC
> 1000
Output voltage (Analog) @ ±
I
PN
,
R
L
= 10 kΩ,
T
A
= 25°C ± 10
Output internal resistance
approx.100
Load resistance
> 10
V
mA
A
MΩ
V
kΩ
Advantages
Easy installation
Small size and space savings
Only one design for wide current
ratings range
High immunity against external
interference
Accuracy - Dynamic performance data
X
ε
L
V
OE
V
OH
TCV
OE
TCV
OUT
t
r
t
ra
di/dt
BW
Accuracy @
I
PN
,
T
A
= 25°C (excluding offset)
Linearity error
1)
(0 .. ±
I
PN
)
Electrical offset voltage @
T
A
= 25°C,
I
P
= 0
Hysteresis offset voltage @
I
P
= 0;
after an excursion of 1 x
I
PN
Temperature coefficient of
V
OE
Temperature coefficient of
V
OUT
(% of reading)
Response time to 90% of
I
PN
step
Reaction time @ 10% of
I
PN
di/dt accurately followed
Frequency bandwidth, ± 3 dB, small signal
2)
<±1
%
< ± 0.5 % of
I
PN
< ± 50
mV
< ± 12.5
<±1
< ± 0.05
< 10
<2
> 50
DC .. 3
mV
mV/K
%/K
µs
us
A/µs
kHz
Applications
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Power supplies for welding and
telecom applications.
General data
T
A
T
S
m
Ambient operating temperature
Ambient storage temperature
Housing PBT 30% glassfiber
Mass
Standard
3)
- 25 .. + 85
- 30 .. + 90
°C
°C
Application domain
Industrial
approx. 6
kg
EN 50178:1997
Notes :
1)
2)
3)
Linearity data exclude the electrical offset.
To avoid excessive core heating
Please consult characterisation report for more technical details and
application advice.
Page 1/3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
070219/8
www.lem.com