欢迎访问ic37.com |
会员登录 免费注册
发布采购

HAZ6000-SRI 参数 Datasheet PDF下载

HAZ6000-SRI图片预览
型号: HAZ6000-SRI
PDF下载: 下载PDF文件 查看货源
内容描述: 电流传感器 [Current Transducers]
分类和应用: 传感器
文件页数/大小: 3 页 / 249 K
品牌: LEM [ LEM ]
 浏览型号HAZ6000-SRI的Datasheet PDF文件第2页浏览型号HAZ6000-SRI的Datasheet PDF文件第3页  
Current Transducers HAZ 4000..20000-SRI
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
I
PN
= 4000..20000 A
I
OUT
= 0-20 mA
(T-RMS DC)
Electrical data
Primary nominal
r.m.s. current
I
PN
(A)
4000
6000
10000
12000
14000
20000
Primary current
measuring range
I
P
(A)
±
±
±
±
±
±
4000
6000
10000
12000
14000
20000
Type
HAZ
HAZ
HAZ
HAZ
HAZ
HAZ
4000-SRI
6000-SRI
10000-SRI
12000-SRI
14000-SRI
20000-SRI
Features
Hall effect measuring principle
Galvanic isolation between primary
and secondary circuit
True-rms, 0-20mA DC current output
Isolation voltage 12kV Rms/ 50 Hz
/ 1 min
Low power consumption
Package in PBT meeting UL 94-V0
V
C
I
C
I
OC
R
IS
I
OUT
R
OUT
R
L
Supply voltage (± 5 %)
Current consumption
Overload capacity
Isolation resistance @ 500 VDC
Output current @ ±
I
PN
,
T
A
= 25°C
Output internal resistance
Load resistance
± 15
V
± 50
mA
30,000
A
> 1000
MΩ
0-20
mA DC
approx. 20
< 300
Advantages
Easy mounting
Small size and space savings
Only one design for wide current
ratings range
High immunity against external
interference
Accuracy - Dynamic performance data
X
ε
L
I
OE
I
OM
I
OT
TC
ε
G
t
r
f
Accuracy @
I
PN
,
T
A
= 25°C (without offset)
Linearity error
1)
(0 .. ±
I
PN
)
Electrical offset current,
T
A
= 25°C, @
I
P
= 0
Residual offset current @
I
P
= 0;
after an excursion of 1 x
I
PN
Thermal drift of
I
OE
Thermal drift of the gain (% of reading)
Response time @ 90% of
I
PN
Frequency range, ±3 dB, small signal
2)
<±1
%
< ± 0.5 % of
I
PN
< ± 0.08
mA
< ± 0.025
<
± 0.05%of
< ± 0.05
< 400
mA
I
PN
/K
Applications
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Power supplies for welding and
telecom applications.
%/K
ms
DC and 15 to 3kHz
General data
T
A
T
S
Ambient operating temperature
Ambient storage temperature
Housing PBT 30% glassfiber
UL94 classification
Mass
Standards
3)
- 25 .. + 85
- 30 .. + 90
°C
°C
Application Domain
V0
approx. 6
kg
EN 50178: 1997
m
Industrial
Notes :
1)
2)
3)
Linearity data exclude the electrical offset.
To avoid excessive core heating.
Please consult characterisation report for more technical details and
application advice.
060428/4
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
Page 1/3