欢迎访问ic37.com |
会员登录 免费注册
发布采购

HTB400-P 参数 Datasheet PDF下载

HTB400-P图片预览
型号: HTB400-P
PDF下载: 下载PDF文件 查看货源
内容描述: 电流传感器 [Current Transducers]
分类和应用: 传感器换能器
文件页数/大小: 2 页 / 637 K
品牌: LEM [ LEM ]
 浏览型号HTB400-P的Datasheet PDF文件第2页  
Current Transducers HTB 50..400-P/SP5
and HTB 50..100-TP/SP5
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
I
PN
= 50 .. 400 A
Electrical data
Primary nominal
current rms
I
PN
(A)
50
100
200
300
400
Primary current
measuring range
I
PM
(A)
±
±
±
±
±
150
300
500
600
600
Type
HTB 50-P/SP5, HTB 50-TP/SP5
1)
HTB 100-P/SP5, HTB 100-TP/SP5
1)
HTB 200-P/SP5
HTB 300-P/SP5
HTB 400-P/SP5
Features
Hall effect measuring principle
Galvanic isolation between primary
V
mA
kV
MΩ
V
kΩ
and secondary circuit
Isolation voltage 2500V
Low power consumption
Primary bus bar option for 50A and
100A version for ease of connection
V
C
I
C
V
d
R
IS
V
OUT
R
OUT
R
L
Supply voltage (± 5 %)
2)
Current consumption
Rms voltage for AC isolation test, 50 Hz, 1 min
Isolation resistance @ 500 VDC
Output voltage (Analog) @ ±
I
PN
,
R
L
= 10 kΩ,
T
A
= 25°C
Output internal resistance
Load resistance
+ 12 .. 15
< 15
2.5
> 500
V
OE
± 1.667
100
10
Special feature
Single power supply from 12V to 15V
Accuracy - Dynamic performance data
X
ε
L
V
OE
V
OH
TCV
OE
TCV
OUT
t
r
BW
< ± 0.5 % of
I
PN
< ± 1.0 mV/K
HTB 100-(T)P..400-P/SP5
< ± 0.5
mV/K
Temperature coefficient of
V
OUT
(% of reading)
< ± 0.05 %/K
Response time to 90% of
I
PN
step
<3
µs
Frequency bandwidth (0 .. -3 dB)
3)
DC .. 50
kHz
Accuracy @
I
PN
,
T
A
= 25°C (excluding offset)
Linearity error (0 .. ±
I
PN
)
Electrical offset voltage @
T
A
= 25°C
Hysteresis offset voltage @
I
P
= 0,
after an excursion of 1 x
I
PN
Temperature coefficient of
V
OE
HTB 50-(T)P/SP5
< ± 1 % of
I
PN
< ± 1 % of
I
PN
Vc/2 ± 30 mV
Advantages
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
Applications
AC variable speed drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
General data
T
A
T
S
m
Ambient operating temperature
Ambient storage temperature
Mass (-TP version)
- 25 .. + 85 °C
- 25 .. + 85 °C
< 30 (< 36) g
Notes :
1)
-TP version is equipped with a primary bus bar.
2)
Operating at +12V
Vc < +15V will reduce measuring range.
3)
Derating is needed to avoid excessive core heating at high frequency.
Page 1/2
070111/1
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com