Current Transducer HTFS 200..800-P I
PN
= 200 - 400 - 800 A
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
All Data are given with a R
L
= 10 kΩ
Electrical data
Primary nominal
r.m.s. current
I
PN
(A)I
P
(A)
200
400
800
Primary current
measuring range
± 300
± 600
± 1200
Type
Features
HTFS 200-P
HTFS 400-P
HTFS 800-P
Hall effect measuring principle
Galvanic isolation between primary
and secondary circuit
Low power consumption
Single power supply +5V
Ratiometric offset
T
A
= -40..+105 °C
Fixation by M3 nuts and screws
V
OUT
V
REF
R
L
k
R
OUT
C
L
V
C
I
C
Analog output voltage @
I
P
V
REF
±(1.25·I
P
/I
PN
) V
I
P
= 0
V
REF
± 0.025
V
1)
Internal Reference - Output voltage
1/2V
C
± 0.025
V
V
REF
Output impedance typ. 200
V
REF
Load impedance
200
kΩ
Output load resistance
2
Output impedance
Max. output capacitive load
Supply voltage (± 5 %)
Current consumption @
V
C
= 5 V
<
10
<
1
5
22
µF
V
mA
Advantages
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
V
REF.
IN/OUT
Accuracy - Dynamic performance data
ε
X
L
TCV
OUT
TCV
REF
TCV
OUT
/
V
REF
TC
ε
G
V
OM
t
ra
t
r
di/dt
f
Accuracy
2)
@
I
PN
,
T
A
= 25°C
Linearity error 0 .. 1.5 x
I
PN
Thermal drift of
V
OUT
@
I
P
= 0
Thermal drift of
V
REF
Thermal drift of
V
OUT
/
V
REF
@
I
P
= 0
Thermal drift of the gain
Residual voltage @
I
P
= 0,
after an overload of 3 x
I
PN DC
Reaction time @ 10 % of
I
PN
Response time @ 90 % of
I
PN
di/dt accurately followed
Output noise (DC ..10 kHz)
(DC .. 1 MHz)
Frequency bandwidth (- 3 dB)
3)
±
±
±
±
±
1
0.5
0.3
0.01
0.2
% of
I
PN
% of
I
PN
mV/K
%/K
mV/K
Applications
Forklift drives
AC variable speed drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
± 0.05
% of reading/K
< ± 0.5
<3
<7
> 100
< 15
< 40
DC .. 20
% of
I
PN
µs
µs
A/µs
mVpp
mVpp
kHz
General data
T
A
T
S
m
Ambient operating temperature
Ambient storage temperature
UL94 classification
Mass
Standards
- 40 .. + 105
°C
- 40 .. + 105
°C
V0
60
g
EN 50178: 1997
Application Domain
Industrial
Notes :
1)
It is possible to overdrive
V
REF
with an external reference voltage
between 2 - 2.8 V providing its ability to sink or source approx. 2.5 mA.
2)
Excluding offset.
3)
Small signal only to avoid excessive heatings of the magnetic core.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
051110/3
Page 1/3
LEM