Current Transducer HTFS 200..800-P/SP2
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
I
PN
= 200 - 400 - 800A
All Data are given with a R
L
= 10 kΩ
Electrical data
Primary nominal
r.m.s. current
I
PN
(A)
200
400
800
Primary current
measuring range
I
P
(A)
±300
±600
±1200
Type
Features
Hall effect measuring principle
Galvanic isolation between primary
and secondary circuit
Low power consumption
Single power supply +5V
Ratiometric offset
T
A
= -40..+105 °C
PCB fixation by 4 Ø1 pins
HTFS 200-P/SP2
HTFS 400-P/SP2
HTFS 800-P/SP2
V
OUT
V
REF
R
L
R
OUT
C
L
V
C
I
C
Analog output voltage @
I
P
I
P
= 0
1)
Internal Reference - Output voltage
V
REF
Output impedance
V
REF
Load impedance
Output load resistance
Output impedance
Max. output capacitive load
Supply voltage (± 5 %)
Current consumption @
V
C
= 5 V
V
REF
±(1.25·I
P
/I
PN
) V
V
REF
± 0.025
V
1/2V
C
± 0.025
V
typ. 200
200
kΩ
2
k
<
10
<
1
µF
5
V
22
mA
Advantages
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
V
REF.
IN/OUT
Accuracy - Dynamic performance data
Accuracy
2)
@
I
PN
,
T
A
= 25°C
ε
L
Linearity 0 .. 1.5 x
I
PN
TCV
OUT
Thermal drift of
V
OUT
@
I
P
= 0
TCV
REF
Thermal drift of
V
REF
TCV
OUT
/
V
REF
Thermal drift of
V
OUT
/
V
REF
@
I
P
= 0
TC
ε
G
Thermal drift of the gain
V
OM
Residual voltage @
I
P
= 0, after an overload of 3 x
I
PN DC
t
ra
Reaction time @ 10 % of
I
PN
t
r
Response time @ 90 % of
I
PN
di/dt
di/dt accurately followed
Output noise (DC ..10 kHz)
(DC .. 1 MHz)
f
Frequency bandwidth (-3 dB)
3)
X
≤±1
≤±0.5
≤±0.3
≤±0.01
≤±0.2
<±0.5
<3
<7
> 100
< 15
< 40
DC .. 20
% of
I
PN
% of
I
PN
mV/K
%/K
mV/K
% of
I
PN
µs
µs
A/µs
mVpp
mVpp
kHz
Applications
Forklift drives
AC variable speed drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
≤±0.05
% of reading/K
General data
T
A
T
S
dCp
dCl
CTI
m
Ambient operating temperature
Ambient storage temperature
Creepage distance
Clearance distance
Comparative tracking index (Group IIIa)
UL94 classification
Mass
Standards
- 40 .. + 105
- 40 .. + 105
>4
>4
220
V0
60
°C
°C
mm
mm
V
g
041222/2
EN 50178 (97-10-01)
LEM Components