欢迎访问ic37.com |
会员登录 免费注册
发布采购

HTY75-P 参数 Datasheet PDF下载

HTY75-P图片预览
型号: HTY75-P
PDF下载: 下载PDF文件 查看货源
内容描述: 电流传感器 [Current Transducer]
分类和应用: 传感器
文件页数/大小: 2 页 / 580 K
品牌: LEM [ LEM ]
 浏览型号HTY75-P的Datasheet PDF文件第2页  
Current Transducer HTY 50..100-P
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
I
PN
= 50 .. 100 A
Electrical data
Primary nominal
current rms
I
PN
(A)
50
75
100
Primary current
measuring range
I
PM
(A)
± 150
± 225
± 300
Type
RoHS since
date code
46115
46013
46067
Features
Hall effect measuring principle
Galvanic isolation between primary
and secondary circuit
Isolation voltage 2500 V
Low power consumption
Extended measuring range(3 x
I
PN
)
HTY 50-P
HTY 75-P
HTY 100-P
V
C
I
C
V
d
R
IS
V
OUT
R
L
Supply voltage (± 5 %)
Current consumption
Rms voltage for AC isolation test, 50 Hz, 1 min
Isolation resistance @ 500 VDC
Output voltage (Analog) @ ±
I
PN
,
R
L
= 10 kΩ,
T
A
= 25°C
Load resistance
± 15
< ± 20
2.5
> 500
±4
> 10
V
mA
kV
MΩ
V
kΩ
Advantages
Easy installation
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
Accuracy-Dynamic performance data
ε
X
L
V
OE
V
OH
TCV
OE
TCV
OUT
t
r
BW
Accuracy @
I
PN
,
T
A
= 25°C (excluding offset)
Linearity error (0 .. ±
I
PN
)
Electrical offset voltage @
T
A
= 25°C
Hysteresis offset voltage @
I
P
= 0,
after an excursion of 1 x
I
PN
Temperature coefficient of
V
OE
< ± 1 % of
I
PN
< ± 1 % of
I
PN
< ± 30
mV
< ± 15
mV
typ. ± 2.0
mV/K
max. ± 3.0
mV/K
Temperature coefficient of
V
OUT
(% of reading)
< ± 0.1
%/K
Response time to 90% of
I
PN
step
<7
µs
1)
Frequency bandwidth (- 3 dB)
DC .. 50
kHz
Applications
DC motor drives
Switched Mode Power Supplies
(SMPS)
AC variable speed drives
Uninterruptible Power Supplies
(UPS)
Battery supplied applications
Inverters
General data
T
A
T
S
m
Ambient operating temperature
Ambient storage temperature
Mass
- 10 .. + 75
- 15 .. + 85
30
°C
°C
g
Application domain
Industrial
Note :
1)
Derating is needed to avoid excessive core heating at high frequency.
Page 1/2
070116/3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com