欢迎访问ic37.com |
会员登录 免费注册
发布采购

HX03-P 参数 Datasheet PDF下载

HX03-P图片预览
型号: HX03-P
PDF下载: 下载PDF文件 查看货源
内容描述: 电流传感器 [Current Transducer]
分类和应用: 传感器
文件页数/大小: 2 页 / 645 K
品牌: LEM [ LEM ]
 浏览型号HX03-P的Datasheet PDF文件第2页  
Current Transducer HX 03..50-P/SP2
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
I
PN
= 3 .. 50 A
Electrical data
Primary nominal Primary current,
current rms
measuring range
1)
I
PN
(A)
I
PM
(A)
3
5
10
15
20
25
50
±9
± 15
± 30
± 45
± 60
± 75
± 150
Primary conductor
diameter x turns
(mm)
0.6d x 20T
0.8d x 12T
1.1d x 6T
1.4d x 4T
1.6d x 3T
1.6d x 2T
1.2 x 6.3 x 1T
Type
RoHS since
date code
46128
46019
45352
46133
planned
46233
46152
Features
Galvanic isolation between primary
and secondary circuit
Hall effect measuring principle
Isolation voltage 3000V
Low power consumption
Extended measuring range(3x
I
PN
)
Insulated plastic case recognized
according to UL94-V0.
HX 03-P/SP2
HX 05-P/SP2
HX 10-P/SP2
HX 15-P/SP2
HX 20-P/SP2
HX 25-P/SP2
HX 50-P/SP2
V
OUT
R
OUT
R
L
V
C
I
C
V
d
V
e
V
W
Output voltage (Analog) @ ±
I
PN
,
R
L
= 2 kΩ,
T
A
= 25°C
Output internal resistance
Load resistance
Supply voltage (± 5 %)
Current consumption
Rms voltage for AC isolation test, 50 Hz, 1 min
Partial discharge extinction voltage rms @ 10 pC
Impulse withstand voltage, 1.2/50 µs
V
OE
± 0.625
< 50
2
+ 12 .. 15
< 15
>3
1
6
V
kΩ
V
mA
kV
kV
kV
Special feature
Single supply from +12V to +15V
Advantages
Low insertion losses
Easy to mount with automatic
Accuracy-Dynamic performance data
X
ε
L
V
OE
V
OH
TCV
OE
TCV
OUT
t
r
BW
Accuracy @
I
PN
,
T
A
= 25°C (excluding offset)
Linearity error (0 .. ±
I
PN
)
Electrical offset voltage @
T
A
= 25°C
Hysteresis offset voltage @
I
P
= 0;
after an excursion of 1 x
I
PN
Temperature coefficient of
V
OE
Temperature coefficient of
V
OUT
(% of reading)
Response time to 90% of
I
PN
step
Frequency bandwidth (- 3 dB)
2)
< ± 1 % of
I
PN
< ± 1 % of
I
PN
+ 2.5V ± 50 mV
< ± 10
< ± 1.5
± 0.1
3
50
mV
mV/K
%/K
µs
kHz
handling system
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
Applications
Switched Mode Power Supplies
(SMPS)
AC variable speed drives
Uninterruptible Power Supplies
(UPS)
Electrical appliances
Battery supplied applications
DC motor drives
General data
T
A
T
S
m
dCp
Ambient operating temperature
Ambient storage temperature
Mass
Creepage distance
Isolation material group
Standards
- 25 .. + 85 °C
- 25 .. + 85 °C
8
g
5.5
mm
I
EN50178: 1997
Application domain
Industrial
Notes :
1)
2)
With
R
L
=2kΩ
Small signal only to avoid excessive heating of the magnetic core
Page 1/2
061026/5
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com