欢迎访问ic37.com |
会员登录 免费注册
发布采购

HX03-P_06 参数 Datasheet PDF下载

HX03-P_06图片预览
型号: HX03-P_06
PDF下载: 下载PDF文件 查看货源
内容描述: 电流传感器 [Current Transducer]
分类和应用: 传感器
文件页数/大小: 2 页 / 644 K
品牌: LEM [ LEM ]
 浏览型号HX03-P_06的Datasheet PDF文件第2页  
Current Transducer HX 03..50-P
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
I
PN
= 3 .. 50 A
Electrical data
Primary nominal
current rms
I
PN
(A)
3
5
10
15
20
25
50
Primary current,
measuring range
I
PM
(A)
±9
± 15
± 30
± 45
± 60
± 75
± 150
Primary conductor
diameter x turns
(mm)
0.6d x 20T
0.8d x 12T
1.1d x 6T
1.4d x 4T
1.6d x 3T
1.6d x 2T
1.2 x 6.3 x 1T
Type
RoHS since
date code
planned
45341
45340
45352
45319
45351
45288
Features
Galvanic isolation between primary
and secondary circuit
Hall effect measuring principle
Isolation voltage 3000V
Low power consumption
Extended measuring range
(3
x
I
PN
)
Power supply from ±12V to ±15V
Insulated plastic case recognized
according to UL94-V0.
HX 03-P
HX 05-P
HX 10-P
HX 15-P
HX 20-P
HX 25-P
HX 50-P
V
OUT
R
OUT
R
L
V
C
I
C
V
d
V
e
V
W
Output voltage (Analog) @ ±
I
PN
,
R
L
= 10 kΩ,
T
A
= 25°C
Output internal resistance
Load resistance
Supply voltage (± 5 %)
1)
Current consumption
Rms voltage for AC isolation test, 50Hz, 1 min
Partial discharge extinction voltage rms @ 10 pC
Impulse withstand voltage, 1.2/50 µs
±4
< 50
10
± 15
< ± 15
>3
1
6
V
kΩ
V
mA
kV
kV
kV
Advantages
Low insertion losses
Easy to mount with automatic
handling system
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
Accuracy-Dynamic performance data
X
ε
L
V
OE
V
OH
TCV
OE
TCV
OUT
t
r
BW
Accuracy @
I
PN
,
T
A
= 25°C (excluding offset)
Linearity error (0 .. ±
I
PN
)
Electrical offset voltage,
T
A
= 25°C
Hysteresis offset voltage @
I
P
= 0;
after an excursion of 1 x
I
PN
Temperature coefficient of
V
OE
Temperature coefficient of
V
OUT
(% of reading)
Response time to 90% of
I
PN
step
Frequency bandwidth (- 3 dB)
2)
< ± 1 % of
I
PN
< ± 1 % of
I
PN
< ± 40
mV
< ± 15
< ± 1.5
± 0.1
3
50
mV
mV/K
%/K
µs
kHz
Applications
Switched Mode Power Supplies
(SMPS)
AC variable speed drives
Uninterruptible Power Supplies
(UPS)
Electrical appliances
Battery supplied applications
DC motor drives
General data
T
A
T
S
m
dCp
Ambient operating temperature
Ambient storage temperature
Mass
Creepage distance
Isolation material group
Standards
- 25 .. + 85 °C
- 25 .. + 85 °C
8
g
5.5
mm
I
EN50178: 1997
Application domain
Industrial
Notes :
1)
Also operate at ±12V power supplies, measuring range reduced to ±2.5x
I
PN
2)
Small signal only to avoid excessive heating of the magnetic cores
Page 1/2
061026/10
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com