欢迎访问ic37.com |
会员登录 免费注册
发布采购

HX10-NP 参数 Datasheet PDF下载

HX10-NP图片预览
型号: HX10-NP
PDF下载: 下载PDF文件 查看货源
内容描述: 电流传感器 [Current Transducer]
分类和应用: 传感器
文件页数/大小: 2 页 / 621 K
品牌: LEM [ LEM ]
 浏览型号HX10-NP的Datasheet PDF文件第2页  
Current Transducer HX 05 .. 15-NP
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
I
PN
=
5 .. 15 A
Electrical data
Primary nominal
current rms
I
PN
(A)
Serial
±5
± 10
± 15
Parallel
± 10
± 20
± 30
Primary current,
measuring range
I
PM
(A)
Series
± 15
± 30
± 45
Parallel
± 30
± 60
± 90
0.8d x (6T+6T)
1.0d x (3T+3T)
1.2d x (2T+2T)
HX 05-NP
HX 10-NP
HX 15-NP
planned
planned
46047
Primary conductor
diameter x turns
(mm)
Type
RoHS since
date code
Features
Galvanic isolation between primary
and secondary circuit
Hall effect measuring principle
Isolation voltage 3000V
2 isolated primary windings
Low power consumption
Extended measuring range(3 x
I
PN
)
Power supply from ±12V to ±15V
Insulated plastic case recognized
according to UL94-V0.
V
OUT
R
OUT
R
L
V
C
I
C
V
d
V
e
V
W
Output voltage (Analog) @ ±
I
PN
,
R
L
= 10 kΩ,
T
A
= 25°C
Output internal resistance
Load resistance
Supply voltage (± 5 %)
1)
Current consumption
Rms voltage for AC isolation test, 50 Hz, 1 min
Primary to secondary
Primary 1 to primary 2
Partial discharge extinction voltage rms @ 10 pC
Impulse withstand voltage, 1.2/50 µs
±4
< 50
10
± 15
< ± 15
>3
>1
1
6
V
kΩ
V
mA
kV
kV
kV
kV
Advantages
Low insertion losses
Easy to mount with automatic
handling system
Only one design for wide current
ratings range
Small size and space saving
High immunity to external
interference.
Accuracy-Dynamic performance data
X
ε
L
V
OE
V
OH
TCV
OE
TCV
OUT
t
r
BW
Accuracy @
I
PN
,
T
A
= 25°C (excluding offset)
Linearity error (0 .. ±
I
PN
)
Electrical offset voltage @
T
A
= 25°C
Hysteresis offset voltage @
I
P
= 0;
after an excursion of 1 x
I
PN
Temperature coefficient of
V
OE
Temperature coefficient of
V
OE
(% of reading)
Response time to 90% of
I
PN
step
Frequency bandwidth (- 3 dB)
2)
< ± 1 % of
I
PN
< ± 1 % of
I
PN
< ± 40
mV
< ± 15
< ± 1.5
± 0.1
3
50
mV
mV/K
%/K
µs
kHz
Applications
Switched Mode Power Supplies
(SMPS)
AC variable speed drives
Uninterruptible Power Supplies
(UPS)
Electrical appliances
Battery supplied applications
DC motor drives
General data
T
A
T
S
m
dCp
Ambient operating temperature
Ambient storage temperature
Mass
Creepage distance
Isolation material group
Standards
1)
- 25 .. + 85 °C
- 25 .. + 85 °C
8
g
5.5
mm
I
EN50178: 1997
Application domain
Industrial
Notes : Also operate at ±12V power supplies, measuring range reduced to ±2.5x
I
PN
2)
Small signal only to avoid excessive heating of the magnetic core
Page 1/2
061026/7
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com