欢迎访问ic37.com |
会员登录 免费注册
发布采购

HY10-P 参数 Datasheet PDF下载

HY10-P图片预览
型号: HY10-P
PDF下载: 下载PDF文件 查看货源
内容描述: 电流传感器 [Current Transducers]
分类和应用: 传感器换能器
文件页数/大小: 2 页 / 669 K
品牌: LEM [ LEM ]
 浏览型号HY10-P的Datasheet PDF文件第2页  
Current Transducers HY 5..25-P
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
I
PN
=
5 .. 25 A
Electrical data
Primary nominal
current rms
I
PN
(A)
5
10
12.5
15
20
25
Primary current,
measuring range
I
PM
(A)
±
±
±
±
±
±
15
30
37.5
45
60
75
Primary
conductor
(mm)
0.7
1.1
1.4
1.4
2 x
1.2
2 x
1.4
Type
RoHS since
date code
Features
HY 5-P
HY 10-P
HY 12-P
HY 15-P
HY 20-P
HY 25-P
45260
45286
45264
45276
46097
45269
Hall effect measuring principle
Galvanic isolation between primary
and secondary circuit
Isolation voltage 2500 V~
Compact design for PCB mounting
Low power consumption
Extended measuring range (3 x
I
PN
)
Insulated plastic case recognized
according to UL 94-V0.
1)
1)
V
C
I
C
Î
P
V
d
V
b
R
IS
V
OUT
R
OUT
R
L
Supply voltage (± 5 %)
6)
Current consumption
Overload capability (1 ms)
Rms voltage for AC isolation test, 50 Hz, 1 min
Rated isolation voltage rms
Isolation resistance @ 500 VDC
Output voltage (Analog) @ +
I
PN
,
R
L
= 10 kΩ,
T
A
= 25°C
Output internal resistance
Load resistance
± 12 .. 15
± 10
50 x
I
PN
2.5
500
2)
> 1000
±4
100
>1
V
mA
kV
V
MΩ
V
kΩ
Advantages
Easy mounting
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
Accuracy - Dynamic performance data
X
ε
L
V
OE
V
OH
TCV
OE
TCV
OUT
t
r
di/dt
BW
Accuracy @
I
PN
,
T
A
= 25°C (excluding offset)
Linearity error
3)
(0 .. ±
I
PN
)
Electrical offset voltage@
T
A
= 25°C
Hysteresis offset voltage @
I
P
= 0;
after an excursion of 1 x
I
PN
Temperature coefficient of
V
OE
<±1
<±1
< ± 40
%
% of
I
PN
mV
mV
mV/K
mV/K
%/K
µs
A/µs
kHz
Applications
Static converters for DC motor drives
Switched Mode Power Supplies
(SMPS).
AC variable speed drives
Uninterruptible Power Supplies
(UPS)
Battery supplied applications
General purpose inverters
< ± 15
typ. ± 1.5
max. ± 3
Temperature coefficient of
V
OUT
(% of reading)
< ± 0.1
Response time to 90% of
I
PN
step
<3
di/dt accurately followed
> 50
4)
Frequency bandwidth (- 3 dB)
DC .. 50
General data
T
A
T
S
m
Ambient operating temperature
Ambient storage temperature
Mass
Standards
5)
1)
2)
3)
4)
- 10 .. + 80 °C
- 25 .. + 85 °C
< 14
g
EN 50178: 1997
Application domain
Industrial
Notes :
5)
6)
Conductor terminals are soldered together.
Pollution class 2, overvoltage category III.
Linearity data exclude the electrical offset.
Please refer to derating curves in the technical file to avoid excessive
core heating at high frequency.
Please consult characterisation report for more technical details and
application advice.
Operating at ±12V
Vc < ±15V will reduce measuring range.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/2
061027/8