Current Transducers HY 5 to 25-P
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit
(high power) and the secondary circuit (electronic circuit).
I
PN
=
5 .. 25 A
Electrical data
Primary nominal
r.m.s. current
I
PN
(A)
5
10
12.5
15
20
25
Primary current
measuring range
I
P
(A)
±
15
±
30
±
37.5
±
45
±
60
±
75
Primary
conductor
(mm)
Type
Features
HY 5-P
HY 10-P
HY 12-P
HY 15-P
HY 20-P
HY 25-P
∅
0.7
∅
1.1
∅
1.4
∅
1.4
2 x
∅
1.2
1)
2 x
∅
1.4
1)
•
Hall effect measuring principle
•
Galvanic isolation between primary
and secondary circuit
•
Isolation voltage 2500 V~
•
Compact design for PCB mounting
•
Low power consumption
•
Extended measuring range (3 x
I
PN
)
•
Insulated plastic case recognized
according to UL 94-V0.
V
C
I
C
Î
P
V
d
V
b
R
IS
V
OUT
R
OUT
R
L
Supply voltage (± 5 %)
6)
Current consumption
Overload capability (1 ms)
R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn
R.m.s. rated voltage, safe separation
Isolation resistance @ 500 VDC
Output voltage @ ±
I
PN
,
R
L
= 10 kΩ,
T
A
= 25°C
Output internal resistance
Load resistance
±12 .. ±15
±10
50 x
I
PN
2.5
500
2)
> 1000
±4
100
>1
V
mA
kV
V
MΩ
V
Ω
kΩ
Advantages
•
Easy mounting
•
Small size and space saving
•
Only one design for wide current
ratings range
•
High immunity to external
interference.
Accuracy - Dynamic performance data
X
ε
L
V
OE
V
OH
V
OT
TC
ε
G
t
r
di/dt
f
Accuracy @
I
PN
,
T
A
= 25°C (without offset)
Linearity
3)
(0 .. ±
I
PN
)
Electrical offset voltage,
T
A
= 25°C
Hysteresis offset voltage @
I
P
= 0;
after an excursion of 1 x
I
PN
Thermal drift of
V
OE
Thermal drift of the gain (% of reading)
Response time @ 90% of
I
P
di/dt accurately followed
Frequency bandwidth
4)
(- 3 dB)
< ±1
< ±1
< ±40
%
% of
I
PN
mV
Applications
•
General purpose inverters
•
AC variable speed drives
•
Static converters for DC motor drives
•
Battery supplied applications
•
Uninterruptible Power Supplies
(UPS)
•
Switched Mode Power Supplies
(SMPS).
typ.
max.
< ±15
mV
±1.5
mV/K
±3
mV/K
< ±0.1
%/K
<3
µs
> 50
A/µs
DC .. 50
kHz
General data
T
A
T
S
m
Ambient operating temperature
Ambient storage temperature
Mass
Standards
5)
1)
2)
-10 .. +80
-25 .. +85
< 14
EN 50178
°C
°C
g
Notes :
Conductor terminals are soldered together.
Pollution class 2, overvoltage category III.
3)
Linearity data exclude the electrical offset.
4)
Please refer to derating curves in the technical file to avoid excessive
core heating at high frequency.
5)
Please consult characterisation report for more technical details and
application advice.
6)
Operating at ±12V
≤
Vc < ±15V will reduce measuring range.
030402/4
LEM Components
www.lem.com