 浏览型号LA150-P_06的Datasheet PDF文件第2页  
Current Transducer LA 150-P
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
I
PN
= 150 A
46090
Electrical data
I
PN DC
I
PN
I
PM
R
M
Primary continuous direct current (nominal)
150
A
Primary nominal current rms
106
A
Primary current, measuring range
0 .. ± 200
A
Measuring resistance
T
A
= 70°C
T
A
= 85 °C
R
M mini
R
M maxi
R
M mini
R
M maxi
@ ±15V, ± 200 A
maxi
0
30
0
15
Secondary current
75
mA
Secondary nominal current rms
53
mA
Conversion ratio
1 : 2000
Supply voltage (± 5 %)
± 15
V
Current consumption
16 +
I
S
mA
Rms voltage for AC isolation test, 50 Hz,1min
2.5
kV
Features
Closed loop (compensation) current
transducer using the Hall effect
Printed circuit board mounting
I
S
I
SN
K
N
V
C
I
C
V
d
Advantages
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capacity
Accuracy-Dynamic performance data
X
ε
L
I
OE
I
OM
I
OT
t
r
di/dt
BW
Accuracy @
I
PN DC
,
T
A
= 25°C, ± 15 V (± 5 %)
Linearity error (0 .. ±
I
PN DC
)
Electrical offset current @
I
P
= 0,
T
A
= 25°C
Magnetic offset current @
I
P
= 0 and specified
R
M
,
after an overload of 1 x
I
PN DC
Temperature variation of
I
O
Response time to 90% of
I
PN DC
step
di/dt accurately followed
Frequency bandwidth (- 1 dB)
1)
< ± 1 % of
I
PN DC
± 0.25% of
I
PN DC
< ± 0.2
mA
< ± 0.15
mA
< ± 0.005 mA
<1
µs
> 200
A/µs
DC .. 150 kHz
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications
General data
T
A
T
S
R
S
m
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance
Mass
Standards
- 10 .. + 80 °C
- 15 .. + 85 °C
80
25
g
EN 50178: 1997
Application Domain
Industrial
Notes :
1)
Derating is needed to avoid excessive core heating at high frequency.
Page 1/2
061110/7
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com