欢迎访问ic37.com |
会员登录 免费注册
发布采购

LA25-SP11 参数 Datasheet PDF下载

LA25-SP11图片预览
型号: LA25-SP11
PDF下载: 下载PDF文件 查看货源
内容描述: 电流传感器 [Current Transducer]
分类和应用: 传感器
文件页数/大小: 2 页 / 251 K
品牌: LEM [ LEM ]
 浏览型号LA25-SP11的Datasheet PDF文件第2页  
Current Transducer LA 25-NP/SP11
For the electronic measurement of currents : DC, AC, pulsed,
mixed, with a galvanic isolation between the primary circuit
(high power) and the secondary circuit (electronic circuit).
I
PN
=
1 A
16095
Electrical data
I
PN
I
P
R
M
Primary nominal r.m.s. current
Primary current, measuring range
Measuring resistance
with ± 15 V
I
SN
K
N
V
C
I
C
V
d
V
b
@ ± 1.0 A
max
@ ± 1.5 A
max
1
0 .. ± 1.5
R
M min
R
M max
100
100
320
190
A
A
mA
V
mA
kV
V
V
Features
Closed loop (compensated) multi-
turns current transducer using the
Hall effect
Insulated plastic case recognized
according to UL 94-V0.
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
R.m.s. rated voltage
1)
, safe separation
basic isolation
25
25 : 1000
± 15
10 +
I
S
2.5
600
1700
Special features
I
PN
= 1 A
I
P
= 0 .. ± 1.5 A
K
N
= 25 : 1000.
Accuracy - Dynamic performance data
X
Advantages
± 0.5
< 0.2
Typ
± 0.05
± 0.05
± 0.06
± 0.10
Max
± 0.15
± 0.15
± 0.25
± 0.35
%
%
mA
mA
mA
mA
µs
kHz
ε
L
Typical accuracy @
I
PN
,
T
A
= 25°C
Linearity
Offset current @
I
P
= 0,
T
A
= 25°C
Residual current
3)
@
I
P
= 0, after an overload of 3 x
I
PN
Thermal drift of
I
O
0°C .. + 25°C
+ 25°C .. + 70°C
Response time
4)
@ 90 % of
I
P max
Frequency bandwidth (- 1 dB)
2)
I
O
I
OM
I
OT
t
r
f
<1
DC .. 150
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Applications
General data
T
A
T
S
R
P
R
S
L
P
R
IS
m
Ambient operating temperature
Ambient storage temperature
Primary coil resistance @
T
A
= 25°C
Secondary coil resistance @
T
A
= 70°C
Primary insertion inductance
Isolation resistance @ 500 V,
T
A
= 25°C
Mass
Standards
1)
2)
3)
4)
AC variable speed drives and servo
0 .. + 70
°C
- 25 .. + 85
°C
< 51
m
110
31
µH
> 1500
MΩ
22
g
EN 50178 : 1997
Notes :
Pollution class 2
Measurement carried out after 15 mn functioning
The result of the coercive field of the magnetic circuit
With a di/dt of 100 A/µs.
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
060405/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
Page 1/2
LEM