Current Transducer LA 25-NP/SP7
For the electronic measurement of currents : DC, AC, pulsed,
mixed, with a galvanic isolation between the primary circuit
(high power) and the secondary circuit (electronic circuit).
I
PN
=
2.5 A
16160
Electrical data
I
PN
I
PM
R
M
Primary nominal current rms
Primary current, measuring range
Measuring resistance
@ ± 2.5 A
maxi
@ ± 3.6 A
maxi
Secondary nominal current rms
Conversion ratio
Supply voltage (± 5 %)
Current consumption
with ± 15 V
2.5
0 .. ± 3.6
R
M mini
R
M maxi
100
320
100
190
25
10 : 1000
± 15
10 +
I
S
A
A
Ω
Ω
mA
V
mA
Features
•
Closed loop (compensated) multi-
turns current transducer using the
Hall effect
•
Isolated plastic case recognized
according to UL 94-V0.
I
SN
K
N
V
C
I
C
Special features
•
I
PN
= 2.5 A
•
I
PM
= 0 .. ± 3.6 A
•
K
N
= 10 : 1000.
Accuracy - Dynamic performance data
X
ε
L
Typical accuracy @
I
PN
,
T
A
= 25°C
Linearity error
Offset current @
I
P
= 0,
T
A
= 25°C
Magnetic offset current
3)
@
I
P
=
0, after an overload of 3 x
I
PN
Temperature variation of
I
O
0°C .. + 25°C
+ 25°C .. + 70°C
Response time
4)
to 90 % of
I
PN
step
Frequency bandwidth (- 1 dB)
2)
± 0.5
< 0.2
Typ Maxi
± 0.05 ± 0.15
± 0.05 ± 0.15
± 0.06 ± 0.25
± 0.10 ± 0.35
<1
DC .. 150
%
%
mA
mA
mA
mA
µs
kHz
Advantages
•
•
•
•
•
•
•
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
•
Current overload capability.
I
O
I
OM
I
OT
t
r
BW
General data
T
A
T
S
R
P
R
S
L
P
R
IS
m
Ambient operating temperature
Ambient storage temperature
Primary coil resistance @
T
A
= 25°C
Secondary coil resistance @
T
A
= 70°C
Insertion inductance
Isolation resistance @ 500 V,
T
A
= 25°C
Mass
Standards
0 .. + 70
°C
- 25 .. + 85
°C
< 8.5
m
Ω
110
Ω
5.5
µH
> 1500
MΩ
22
g
EN 50178: 1997
Applications
•
AC variable speed drives and servo
•
•
•
•
•
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
Application Domain
Notes:
1)
2)
3)
4)
Pollution class 2
Measurement carried out after 15 mn functioning
The result of the coercive field of the magnetic circuit
With a di/dt of 100 A/µs.
•
Industrial.
Page 1/3
070305/4
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
w w w .lem.com