Current Transducer LA 35-NP
For the electronic measurement of currents : DC, AC, pulsed,
mixed, with a galvanic isolation between the primary circuit
(high power) and the secondary circuit (electronic circuit).
I
PN
= 7-8-11-17-35 A
16136
Electrical data
I
PN
I
P
R
M
Primary nominal r.m.s. current
Primary current, measuring range
Measuring resistance
with ± 15 V
I
SN
K
N
V
C
I
C
V
d
V
b
@ ± 35 At
@ ± 70 At
max
max
35
1)
0 .. ± 70
R
M min
R
M max
60
60
150
85
At
At
Features
Closed loop (compensated) multi-
range current transducer using the
Hall effect
Printed circuit board mounting
Insulated plastic case recognized
according to UL 94-V0.
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
R.m.s. rated voltage
2)
, safe separation
basic isolation
35
mA
1-2-3-4-5 : 1000
± 15
V
10 +
I
S
mA
2.5
kV
600
V
1700
V
Advantages
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Accuracy - Dynamic performance data
X
ε
L
Typical accuracy @
I
PN,
T
A
= 25°C
Linearity
Offset current @
I
P
= 0,
T
A
= 25°C
Residual current
4)
@
I
P
= 0, after an overload of 3 x
I
PN
Thermal drift of
I
O
- 25°C .. + 70°C
Response time @ 90 % of
I
PN
di/dt accurately followed
Frequency bandwidth (- 1 dB)
5)
3)
± 0.5
< 0.2
Typ
± 0.10
± 0.05
± 0.15
Max
± 0.20
± 0.15
± 0.50
%
%
mA
mA
mA
µs
A/µs
kHz
I
O
I
OM
I
OT
t
r
di/dt
f
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
<1
> 50
DC .. 150
General data
T
A
T
S
R
P
R
S
R
IS
m
Ambient operating temperature
Ambient storage temperature
Primary resistance per turn @
T
A
= 25°C
Secondary coil resistance @
T
A
= 70°C
Isolation resistance @ 500 V,
T
A
= 25°C
Mass
Standards
- 25 .. + 70
°C
- 40 .. + 85
°C
< 1.25
m
80
> 1500
MΩ
22
g
EN 50178 : 1997
Notes :
1)
2)
3)
4)
5)
In order to avoid over-heating, it is necessary that the recommended
primary connections be followed (see table page 2).
Pollution class 2
Measurement carried out after 15 mn functioning
The result of the coercive field of the magnetic circuit
With a di/dt of 100 A/µs.