Dimensions LA 55-P
(in mm. 1 mm = 0.0394 inch)
Left view
Bottom view
Model + N° SP
Connection
Front view
Mechanical characteristics
•
General tolerance
•
Primary through-hole
•
Fastening & connection of secondary
Recommended PCB hole
± 0.2 mm
12.7 x 7 mm
3 pins
0.63 x 0.56mm
0.9 mm
Safety
This transducer must be used in electric/electronic
equipment with respect to applicable standards and
safety requirements in accordance with the
manufacturer's operating instructions.
Remarks
•
I
S
is positive when
I
P
flows in the direction of the arrow.
•
Temperature of the primary conductor should not exceed
90°C.
•
Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
•
In order to achieve the best magnetic coupling, the primary
windings have to be wound over the top edge of the device.
•
This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
070103/11
Caution, risk of electrical shock
When operating the transducer, certain parts of the module
can carry hazardous voltage (eg. primary busbar, power
supply).
Ignoring this warning can lead to injury and/or cause
serious damage.
This transducer is a built-in device, whose conducting
parts must be inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
page 2/2