欢迎访问ic37.com |
会员登录 免费注册
发布采购

LAH100-P 参数 Datasheet PDF下载

LAH100-P图片预览
型号: LAH100-P
PDF下载: 下载PDF文件 查看货源
内容描述: 电流传感器LAH 100 -P [Current Transducer LAH 100-P]
分类和应用: 传感器
文件页数/大小: 2 页 / 44 K
品牌: LEM [ LEM ]
 浏览型号LAH100-P的Datasheet PDF文件第2页  
Current Transducer LAH 100-P
For the electronic measurement of currents : DC, AC, pulsed ...,
with a galvanic isolation between the primary circuit
(high power) and the secondary circuit (electronic circuit).
I
PN
= 100 A
Electrical data
I
PN
I
P
R
M
Primary nominal r.m.s. current
Primary current, measuring range
1)
Measuring resistance @
with ± 12 V
100
0 .. 160
T
A
= 70°C
T
A
= 85°C
R
M min
R
M max
R
M min
R
M max
A
A
Features
Closed loop (compensated) current
transducer using the Hall effect
Printed circuit board mounting
Insulated plastic case recognized
according to UL 94-V0.
I
SN
K
N
V
C
I
C
V
d
V
e
V
w
X
@
I
PN
[± A
DC
]
0
63
0
57
2)
@
I
PN
[A
RMS
]
0
11
0
5
with ± 15 V
@
I
PN
[± A
DC
]
20 120 45 114
2)
@
I
PN
[A
RMS
]
20 51
45 45
3)
@
I
P
<
I
PN
Secondary nominal r.m.s. current
50
Conversion ratio
1 : 2000
Supply voltage (± 5 %)
± 12 .. 15
Current consumption
10
(@ ± 15 V)+I
S
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn
5
R.m.s. voltage for partial discharge extinction @ 10 pC > 2
Impulse withstand voltage 1.2/50 µs
> 12
mA
V
mA
kV
kV
kV
Advantages
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Accuracy - Dynamic performance data
ε
L
Accuracy
4)
@
I
PN,
T
A
= 25°C
Linearity
Offset current @
T
A
= 25°C
Residual current @
I
P
= 0, after an overload of 5 x
I
PN
Thermal drift of
I
O
0°C .. + 70°C
- 25°C .. + 85°C
Reaction time @ 10 % of
I
PN
Response time
5)
@ 90 % of
I
PN
di/dt accurately followed
Frequency bandwidth (- 1 dB)
± 0.25
< 0.15
Max
± 0.15
± 0.10 ± 0.15
± 0.10 ± 0.40
± 0.10 ± 0.50
< 200
< 500
> 200
DC .. 200
Typ
%
%
mA
mA
mA
mA
ns
ns
A/µs
kHz
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
I
O
I
OM
I
OT
t
r a
t
r
di/dt
f
General data
T
A
T
S
R
S
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance
Insulating material group
Mass
Standards
6)
1)
3)
@
T
A
= 70°C
@
T
A
= 85°C
m
Notes :
- 25 .. + 85
- 40 .. + 90
115
121
I
24
EN 50178
°C
°C
g
6)
For 10 s, with
R
M
25
(V
C
= ± 15 V) -
2)
50 Hz Sinusoidal
-
The measuring resistance
R
M min
may be lower (see "LAH Technical
Information" leaflet) -
4)
Without
I
O
&
I
OM
-
5)
With a di/dt of 100 A/µs
A list of corresponding tests is available.
010820/5
LEM Components
w w w.lem.com