欢迎访问ic37.com |
会员登录 免费注册
发布采购

LAS100-TP 参数 Datasheet PDF下载

LAS100-TP图片预览
型号: LAS100-TP
PDF下载: 下载PDF文件 查看货源
内容描述: 电流传感器 [Current Transducer]
分类和应用: 传感器
文件页数/大小: 3 页 / 1170 K
品牌: LEM [ LEM ]
 浏览型号LAS100-TP的Datasheet PDF文件第2页浏览型号LAS100-TP的Datasheet PDF文件第3页  
Current Transducer LAS 100-TP
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
I
PN
= 100 A
16059
Electrical data
I
PN
I
P
V
OUT
R
L
R
OUT
V
REF
Primary nominal r.m.s. current
Primary current, measuring range
at frequency > 1 k H z
Analog output voltage @
Output load resistance
Output internal resistance
Internal reference voltage
V
REF
load resistance
V
REF
internal resistance
V
REF
external voltage range
Max. output capacitive load
Supply voltage (± 5 %)
Current consumption @
V
C
= 5 V
100
A
0 .. ± 200
A
0 .. ± 300
A
V
REF
±
(0.625
·
I
P
/I
PN
) V
V
REF
± 0.025
V
2
k
<
20
2.5 ± 0.025
V
1
MΩ
200
2.0 .. 2.8
V
1
nF
5
V
18
mA
Features
Current transducer using
Eta-technology
Unipolar voltage supply
Insulated plastic case recognized
according to UL 94-V0
Compact design for PCB mounting
Extended measuring range.
I
P
I
P
= 0
Advantages
Excellent accuracy
Very good linearity
Very low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
C
L
V
C
I
C
typ
Accuracy - Dynamic performance data
X
ε
L
Accuracy
1)
@
I
PN
,
T
A
= 25°C
Linearity error 0 ..
I
PN 2)
<±1
< 0.7
Typ Max
80 120
50 80
300 500
±5
< 200
< 500
> 100
< 10
DC .. 100
%
%
ppm/K
ppm/K
ppm/K
mV
ns
ns
A/µs
mVpp
kHz
TCV
OUT
Thermal drift of
V
OUT
@
I
P
= 0
- 40°C .. + 85°C
TCV
OUT
/
V
REF
Thermal drift of
V
OUT
/
V
REF
@
I
P
= 0 - 40°C .. + 85°C
TC
ε
G
Thermal drift of the gain
- 40°C .. + 85°C
V
OM
Residual voltage @
I
P
= 0, after an overload of 2 x
I
PN DC
t
ra
Reaction time @ 10 % of
I
PN
t
r
Response time @ 90 % of
I
PN
di/dt
di/dt accurately followed
Output noise without external filter
f
Frequency bandwidth (- 1 dB)
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding
applications.
General data
T
A
T
S
m
Ambient operating temperature
Ambient storage temperature
Mass
Standards
- 40 .. + 85
°C
- 40 .. + 100
°C
20
g
EN 50178 : 1997
Application domain
Industrial.
All Data are given with a R
L
= 10 kΩ.
Notes :
1)
Excluding electrical, magnetic offsets and linearity
2)
Including magnetic offset.
Copyright protected.
060303/6
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
page 1/3
LEM