Current Transducer LF 205-S
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
I
PN
=
200 A
16135
Electrical data
I
PN
I
P
R
M
Primary nominal r.m.s. current
Primary current, measuring range
Measuring resistance @
with ± 12 V
with ± 15 V
I
SN
K
N
V
C
I
C
@ ± 200 A
max
@ ± 420 A
max
@ ± 200 A
max
@ ± 420 A
max
200
0 .. ± 420
T
A
= 70°C
T
A
= 85°C
R
M min
R
M max
R
M min
R
M max
0
0
0
0
71
14
100
28
0
0
23
23
69
12
98
26
A
A
Features
•
Closed loop (compensated) current
transducer using the Hall effect
•
Insulated plastic case recognized
according to UL 94-V0.
Ω
Ω
Ω
Ω
mA
V
mA
Advantages
•
•
•
•
•
•
•
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
•
Current overload capability.
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption @ ± 15 V
100
1 : 2000
± 12 .. 15
17 +
I
S
Accuracy - Dynamic performance data
X
G
ε
L
Overall accuracy @
I
PN
,
T
A
= 25°C
Linearity error
Offset current @
I
P
= 0,
T
A
= 25°C
Residual current
1)
@
I
P
= 0, after an overload of 3 x
I
PN
Thermal drift of
I
O
- 40°C .. + 85°C
Reaction time @ 10 % of
I
PN
Response time
2)
@ 90 % of
I
PN
di/dt accurately followed
Frequency bandwidth (- 3 dB)
± 0.5
< 0.1
Max
± 0.2
± 0.1
± 0.12 ± 0.4
< 500
<1
> 100
DC .. 100
Typ
%
%
mA
mA
mA
ns
µs
A/µs
kHz
I
O
I
OM
I
O T
t
ra
t
r
di/dt
f
Applications
•
AC variable speed drives and servo
•
•
•
•
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
General data
T
A
T
S
R
S
m
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @
T
A
= 70°C
@
T
A
= 85°C
Mass
Standards
- 40 .. + 85
°C
- 40 .. + 90
°C
33
Ω
35
Ω
78
g
EN 50178 : 1997
•
Application domain
•
Industry.
Notes :
1)
2)
The result of the coercive field of the magnetic circuit
With a di/dt of 100 A/µs.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
060522/11
Page 1/3
LEM
w w w .lem.com