型号: LF205P
PDF下载: 下载PDF文件 查看货源
内容描述: 电流传感器LF 205 -P / SP1 [Current Transducer LF 205-P/SP1]
分类和应用: 传感器
文件页数/大小: 2 页 / 75 K
品牌: LEM [ LEM ]
 浏览型号LF205P的Datasheet PDF文件第2页  
Current Transducer LF 205-P/SP1
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
I
PN
=
200 A
Electrical data
I
PN
I
P
R
M
Primary nominal r.m.s. current
Primary current, measuring range
Measuring resistance @
with ± 12 V
with ± 15 V
I
SN
K
N
V
C
I
C
V
d
@ ± 200 A
max
@ ± 420 A
max
@ ± 200 A
max
@ ± 420 A
max
200
0 .. ± 420
T
A
= 70°C
T
A
= 85°C
R
M min
R
M max
R
M min
R
M max
0
0
0
0
71
14
100
28
0
0
23
23
69
12
98
26
A
A
Features
Closed loop (compensated) current
transducer using the Hall effect
Insulated plastic case recognized
according to UL 94-V0.
mA
V
mA
kV
Special features
Mounting clips molded into the
transducer housing, attach to printed
circuit boards 1.6mm thick.
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption @ ± 15V
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
100
1 : 2000
± 12 .. 15
17 +
I
S
3.5
Advantages
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Accuracy - Dynamic performance data
X
G
ε
L
Overall accuracy @
I
PN
,
T
A
= 25°C
Linearity
Offset current @
I
P
= 0,
T
A
= 25°C
Residual current
1)
@
I
P
= 0, after an overload of 3 x
I
PN
Thermal drift of
I
O
- 40°C .. + 85°C
Reaction time @ 10 % of
I
P max
Response time
2)
@ 90 % of
I
P max
di/dt accurately followed
Frequency bandwidth (- 3 dB)
± 0.5
< 0.1
Max
± 0.2
± 0.1
± 0.12 ± 0.4
< 500
<1
> 100
DC .. 100
Typ
%
%
mA
mA
mA
ns
µs
A/µs
kHz
I
O
I
OM
I
OT
t
ra
t
r
di/dt
f
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
General data
T
A
T
S
R
S
m
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @
T
A
= 70°C
@
T
A
= 85°C
Mass
Standards
3)
- 40 .. + 85
- 40 .. + 90
33
35
58
EN 50178
°C
°C
g