Current Transducer LTS 6-NP
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
I
PN
=
6 At
16065
Electrical data
I
PN
I
PM
Î
PDC
V
OUT
N
S
R
L
R
IM
TCR
IM
V
C
I
C
Primary nominal current rms
Primary current, measuring range
Overload capability (direct current)
Output voltage (Analog) @
I
P
I
P
= 0
Number of secondary turns (± 0.1 %)
Load resistance
Internal measuring resistance (± 0.5 %)
Temperature coefficient of
R
IM
Supply voltage (± 5 %)
Current consumption @
V
C
= 5 V
6
At
0 .. ± 19.2
At
250
At
2.5
±
(0.625
·
I
P
/I
PN
) V
2.5
1)
V
2000
2
k
208.33
< 50
ppm/K
5
V
2)
28+
I
S
+(V /R
L
) mA
OUT
Features
Closed loop (compensated) multi-
range current transducer using the
Hall effect
Unipolar voltage supply
Compact design for PCB mounting
Isolated plastic case recognized
according to UL 94-V0
Incorporated measuring resistance
Extended measuring range.
Typ
Accuracy - Dynamic performance data
X
Advantages
± 0.2
± 0.7
< 0.1
Typ
80
%
%
%
Maxi
200 ppm/K
250 ppm/K
50
3)
ppm/K
± 0.5
mV
± 2.0
mV
± 2.0
mV
ns
ns
A/µ s
kHz
kHz
ε
L
Accuracy @
I
PN
,
T
A
= 25°C
Accuracy with
R
IM
@
I
PN
,
T
A
= 25°C
Linearity error
TCV
OUT
Temperature coefficient of
V
OUT
@
I
P
= 0 - 10°C .. + 85°C
- 40°C .. - 10°C
TCG
Temperature coefficient of
G
- 40°C .. + 85°C
V
OM
Residual voltage @
I
P
= 0, after an overload of 3 x
I
PN
5 x
I
PN
10 x
I
PN
t
ra
t
r
di/dt
BW
Reaction time @ 10 % of
I
PN
Response time to 90 % of
I
PN
step
di/dt accurately followed
Frequency bandwidth (0 .. - 0.5 dB)
(- 0.5 .. 1 dB)
Excellent accuracy
Very good linearity
Very low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
< 100
< 400
> 15
DC .. 100
DC .. 200
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding
applications.
General data
T
A
T
S
m
Ambient operating temperature
Ambient storage temperature
Insulating material group
Mass
Standards
4)
- 40 .. + 85
- 40 .. + 100
III a
10
EN 50178: 1997
IEC 60950-1 : 2001
°C
°C
g
Application domain
Industrial.
Copyright protected.
Notes:
1)
2)
3)
4)
Absolute value @
T
A
= 25°C, 2.475 <
V
OUT
< 2.525
I
S
=
I
P
/N
S
Only due to
TCR
IM
Specification according to IEC 61000-4-3 are not guaranteed between
95 and 110 MHz (value higher by 5% than the specification).