欢迎访问ic37.com |
会员登录 免费注册
发布采购

APXW005A0X3-SRZ_1010 参数 Datasheet PDF下载

APXW005A0X3-SRZ_1010图片预览
型号: APXW005A0X3-SRZ_1010
PDF下载: 下载PDF文件 查看货源
内容描述: 9-36V ProLynxTM 5A :非隔离DC-DC电源模块9VDC -36VDC输入; 3VDC到18VDC输出; 5A至2.5A输出电流 [9-36V ProLynxTM 5A: Non-Isolated DC-DC Power Modules 9Vdc –36Vdc input; 3Vdc to 18Vdc output; 5A to 2.5A Output Current]
分类和应用: 电源电路
文件页数/大小: 21 页 / 5069 K
品牌: LINEAGEPOWER [ LINEAGE POWER CORPORATION ]
 浏览型号APXW005A0X3-SRZ_1010的Datasheet PDF文件第1页浏览型号APXW005A0X3-SRZ_1010的Datasheet PDF文件第3页浏览型号APXW005A0X3-SRZ_1010的Datasheet PDF文件第4页浏览型号APXW005A0X3-SRZ_1010的Datasheet PDF文件第5页浏览型号APXW005A0X3-SRZ_1010的Datasheet PDF文件第6页浏览型号APXW005A0X3-SRZ_1010的Datasheet PDF文件第7页浏览型号APXW005A0X3-SRZ_1010的Datasheet PDF文件第8页浏览型号APXW005A0X3-SRZ_1010的Datasheet PDF文件第9页  
Preliminary Data Sheet
9-36V ProLynx
TM
5A: Non-isolated DC-DC Power Modules
October 28, 2010
9 – 36Vdc input; 3Vdc to 18Vdc output; 5A to 2.5A output current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Input Voltage
Continuous
Operating Ambient Temperature
(see Thermal Considerations section)
Storage Temperature
All
T
stg
-55
125
°C
All
T
A
-40
85
°C
Device
All
Symbol
V
IN
Min
-0.3
Max
36
Unit
Vdc
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Operating Input Voltage
Maximum Input Current
(V
IN
=9V to 36V, I
O
=I
O, max
)
Input No Load Current
(V
IN
= 28V, I
O
= 0, module enabled)
(V
IN
= 28V, I
O
= 0, module enabled)
Input Stand-by Current
(V
IN
= 28Vdc, module disabled)
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V
IN
=0 to
36V
,
I
O
= I
Omax
; See Test Configurations)
Input Ripple Rejection (120Hz)
All
All
All
-24
-45
It
2
Device
All
All
Symbol
V
IN
I
IN,max
Min
9
Typ
Max
36
5
Unit
Vdc
Adc
V
O,set
= 3Vdc
V
O,set
= 18Vdc
All
I
IN,No load
I
IN,No load
I
IN,stand-by
26
50
3
mA
mA
mA
0.5
95
-60
As
mAp-p
dB
2
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included;
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies
require a fast-acting fuse with a maximum rating of 8 A (see Safety Considerations section). Based on the
information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a
lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.
LINEAGE
POWER
2