Data Sheet
March 30, 2008
12V Austin Lynx
TM
SIP Non-isolated Power Modules, Programmable:
10Vdc – 14Vdc input; 0.75Vdc to 5.5Vdc Output;10A Output Current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Input Voltage
Continuous
Operating Ambient Temperature
(see Thermal Considerations section)
Storage Temperature
All
T
stg
-55
125
°C
All
T
A
-40
85
°C
Device
All
Symbol
V
IN
Min
-0.3
Max
15
Unit
Vdc
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Operating Input Voltage
Maximum Input Current
(V
IN
= V
IN, min
to V
IN, max
, I
O
=I
O, max
V
O,set
= 3.3Vdc)
Input No Load Current
(V
IN
= 12.0Vdc, I
O
= 0, module enabled)
Input Stand-by Current
(V
IN
= 12.0Vdc, module disabled)
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V
IN, min
to
V
IN, max,
I
O
= I
Omax
; See Test configuration section)
Input Ripple Rejection (120Hz)
All
It
2
Device
All
All
V
O,set
= 0.75Vdc
V
O,set
= 5.0Vdc
All
Symbol
V
IN
I
IN,max
I
IN,No load
I
IN,No load
I
IN,stand-by
Min
10.0
Typ
12.0
Max
14.0
6.5
Unit
Vdc
Adc
mA
mA
mA
40
100
2.0
0.5
As
2
All
20
mAp-p
All
30
dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being
part of a complex power architecture. To preserve maximum flexibility, internal fusing is not included, however, to
achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a 15A,
time-delay fuse (see Safety Considerations section). Based on the information provided in this data sheet on inrush
energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse
manufacturer’s data sheet for further information.
LINEAGE
POWER
2