Data Sheet
March 28, 2008
Absolute Maximum Ratings
Austin Lynx
TM
SIP Non-Isolated dc-dc Power Modules:
3.0 Vdc - 5.5 Vdc Input, 0.9 Vdc - 3.3 Vdc Output, 10 A
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress
ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the
operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the
device reliabiltiy.
Parameter
Input Voltage:
Continuous
Operating Ambient Temperature
Storage Temperature
Device
All
All
All
Symbol
VIN
TA
Tstg
Min
0
–40
–55
Max
6.5
85
125
Unit
Vdc
°C
°C
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Operating Input Voltage
Device
AXH010A0S0R9
AXH010A0S1R0
AXH010A0P
AXH010A0M
AXH010A0Y
AXH010A0D
AXH010A0G
AXH010A0F
Symbol
VIN
VIN
VIN
VIN
VIN
VIN
VIN
VIN
II,max
Min
3.0
3.0
3.0
3.0
3.0
3.0
3.0
4.5
Typ
Max
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
9.5
Unit
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
A
mAp-p
Maximum Input Current
(VI = 0 to VI,max; IO = IO,max)
Input Reflected-Ripple Current
(5 Hz to 20 MHz; 1 µH source impedance; TA = 25
°C; CIN = 200 µF)
Input Ripple Rejection
(100 - 120Hz)
30
40
dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum safety and
system protection, always use an input line fuse. The safety agencies require a time-delay fuse with a maximum rating of 20A.
Lineage Power