欢迎访问ic37.com |
会员登录 免费注册
发布采购

AXH016A0X3-SR12Z 参数 Datasheet PDF下载

AXH016A0X3-SR12Z图片预览
型号: AXH016A0X3-SR12Z
PDF下载: 下载PDF文件 查看货源
内容描述: 3.0 - 5.5V直流输入; 0.75Vdc到3.63Vdc输出; 16A的输出电流 [3.0 - 5.5Vdc input; 0.75Vdc to 3.63Vdc Output; 16A output current]
分类和应用:
文件页数/大小: 21 页 / 684 K
品牌: LINEAGEPOWER [ LINEAGE POWER CORPORATION ]
 浏览型号AXH016A0X3-SR12Z的Datasheet PDF文件第7页浏览型号AXH016A0X3-SR12Z的Datasheet PDF文件第8页浏览型号AXH016A0X3-SR12Z的Datasheet PDF文件第9页浏览型号AXH016A0X3-SR12Z的Datasheet PDF文件第10页浏览型号AXH016A0X3-SR12Z的Datasheet PDF文件第12页浏览型号AXH016A0X3-SR12Z的Datasheet PDF文件第13页浏览型号AXH016A0X3-SR12Z的Datasheet PDF文件第14页浏览型号AXH016A0X3-SR12Z的Datasheet PDF文件第15页  
Data Sheet
August 12, 2008
Austin Superlynx
TM
SMT Non-isolated Power Modules:
3.0 – 5.5Vdc input; 0.75Vdc to 3.63Vdc Output; 16A output current
Design Considerations
(continued)
Output Filtering
The Austin SuperLynx SMT module is designed for low
output ripple voltage and will meet the maximum output
ripple specification with 1 µF ceramic and 10 µF tantalum
capacitors at the output of the module. However,
additional output filtering may be required by the system
designer for a number of reasons. First, there may be a
need to further reduce the output ripple and noise of the
module. Second, the dynamic response characteristics
may need to be customized to a particular load step
change.
To reduce the output ripple and improve the dynamic
response to a step load change, additional capacitance at
the output can be used. Low ESR polymer and ceramic
capacitors are recommended to improve the dynamic
response of the module. For stable operation of the
module, limit the capacitance to less than the maximum
output capacitance as specified in the electrical
specification table.
TM
Safety Considerations
For safety agency approval the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standards,
i.e., UL 60950-1, CSA C22.2 No. 60950-1-03, and VDE
0850:2001-12 (EN60950-1) Licensed.
For the converter output to be considered meeting the
requirements of safety extra-low voltage (SELV), the
input must meet SELV requirements. The power module
has extra-low voltage (ELV) outputs when all inputs are
ELV.
The input to these units is to be provided with a fast-
acting fuse with a maximum rating of 20A in the positive
input lead
.
LINEAGE
POWER
11