欢迎访问ic37.com |
会员登录 免费注册
发布采购

EBVW020A0B9641Z 参数 Datasheet PDF下载

EBVW020A0B9641Z图片预览
型号: EBVW020A0B9641Z
PDF下载: 下载PDF文件 查看货源
内容描述: [36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output]
分类和应用:
文件页数/大小: 18 页 / 1337 K
品牌: LINEAGEPOWER [ LINEAGE POWER CORPORATION ]
 浏览型号EBVW020A0B9641Z的Datasheet PDF文件第8页浏览型号EBVW020A0B9641Z的Datasheet PDF文件第9页浏览型号EBVW020A0B9641Z的Datasheet PDF文件第10页浏览型号EBVW020A0B9641Z的Datasheet PDF文件第11页浏览型号EBVW020A0B9641Z的Datasheet PDF文件第13页浏览型号EBVW020A0B9641Z的Datasheet PDF文件第14页浏览型号EBVW020A0B9641Z的Datasheet PDF文件第15页浏览型号EBVW020A0B9641Z的Datasheet PDF文件第16页  
Data Sheet  
GE  
EBVW020A0B Barracuda Series; DC-DC Converter Power Modules  
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output  
detailed in J-STD-033 Rev. A (Handling, Packing, Shipping and  
Use of Moisture/Reflow Sensitive Surface Mount Devices).  
Moisture barrier bags (MBB) with desiccant are required for MSL  
Post Solder Cleaning and Drying  
Considerations  
ratings of 2 or greater. These sealed packages should not be  
broken until time of use. Once the original package is broken,  
the floor life of the product at conditions of 30°C and 60%  
relative humidity varies according to the MSL rating (see J-STD-  
025A). The shelf life for dry packed SMT packages will be a  
minimum of 12 months from the bag seal date, when stored at  
the following conditions: < 40° C, < 90% relative humidity.  
Post solder cleaning is usually the final circuit-board assembly  
process prior to electrical board testing. The result of  
inadequate cleaning and drying can affect both the reliability of  
a power module and the testability of the finished circuit-board  
assembly. For guidance on appropriate soldering, cleaning and  
drying procedures, refer to GE Board Mounted Power Modules:  
Soldering and Cleaning Application Note (AP01-056EPS).  
EMC Considerations  
The circuit and plots in Figure 24 shows a suggested  
configuration to meet the conducted emission limits of  
EN55022 Class B. For further information on designing for EMC  
compliance, please refer to the FLT007A0 data sheet.  
Level [dBµV]  
80  
70  
60  
+x  
50  
+
x
+
x
40  
30  
20  
10  
0
xx  
x
++  
+
150k 300k 500k  
1M  
2M 3M 4M5M 7M 10M  
30M  
Frequency [Hz]  
x xMES CE0916111952_fin QP  
+ +MES CE0916111952_fin AV  
MES CE0916111952_pre PK  
MES CE0916111952_pre AV  
Figure 24. EMC Considerations.  
July 22, 2013  
©2012 General Electric Company. All rights reserved.  
Page 12