Data Sheet  
ESTW025A0F Series Eighth-Brick Power Modules  
36–75Vdc Input; 3.3Vdc Output; 25A Output  
October 11, 2011  
for natural convection and up to 2.0 m/s (400 ft./min)  
forced airflow, are shown in Figure 15.  
Thermal Considerations  
The power modules operate in a variety of thermal  
environments; however, sufficient cooling should be  
provided to help ensure reliable operation.  
Considerations include ambient temperature, airflow,  
module power dissipation, and the need for increased  
reliability. A reduction in the operating temperature of  
the module will result in an increase in reliability. The  
thermal data presented here is based on physical  
measurements taken in a wind tunnel.  
The thermal reference points, Tref1,Tref2 and Tref3 used  
in the specifications for open frame modules are  
shown in Figures 13a and 13b. For reliable operation  
these temperatures should not exceed 125oC, 110oC  
and 105oC respectively.  
AMBIENT TEMEPERATURE, TA (oC)  
Figure 15. Output Current Derating for the Open  
Frame Module; Airflow in the Transverse Direction  
from Vout(+) to Vout(-); Vin =48V.  
Heat Transfer via Conduction  
The module can also be used in a sealed environment  
with cooling via conduction from the module’s top  
surface through a gap pad material to a cold wall, as  
shown in Figure 16. The output current derating  
versus cold wall temperature, when using a gap pad  
such as Bergquist GP2500S20, is shown in Figure 17.  
Figure 13a. Tref 1 Temperature Measurement  
Location for Open Frame Module.  
Figure 13b. Tref 2 and Tref 3 Temperature  
Measurement Locations for Open Frame Module.  
Figure 16. Cold Wall Mounting  
The thermal reference point, Tref, used in the  
specifications for modules with heatplate is shown in  
Figure 14. For reliable operation this temperature  
should not exceed 110oC.  
COLDPLATE TEMEPERATURE, TC (oC)  
Figure 17. Derated Output Current versus Cold  
Wall Temperature with local ambient temperature  
around module at 85C; Vin=48V.  
Figure 14. Tref Temperature Measurement  
Location for Module with Heatplate.  
Heat Transfer via Convection  
Please refer to the Application Note “Thermal  
Characterization Process For Open-Frame Board-  
Mounted Power Modules” for a detailed discussion of  
thermal aspects including maximum device  
temperatures.  
Increased airflow over the module enhances the heat  
transfer via convection. Derating curves, showing the  
maximum output current that can be delivered by  
each module versus local ambient temperature (TA)  