欢迎访问ic37.com |
会员登录 免费注册
发布采购

ESTW015A0F641-Z 参数 Datasheet PDF下载

ESTW015A0F641-Z图片预览
型号: ESTW015A0F641-Z
PDF下载: 下载PDF文件 查看货源
内容描述: ESTW015A0F系列(八分之一砖)的DC -DC转换器电源模块 [ESTW015A0F Series (Eighth-Brick) DC-DC Converter Power Modules]
分类和应用: 转换器电源电路
文件页数/大小: 17 页 / 903 K
品牌: LINEAGEPOWER [ LINEAGE POWER CORPORATION ]
 浏览型号ESTW015A0F641-Z的Datasheet PDF文件第5页浏览型号ESTW015A0F641-Z的Datasheet PDF文件第6页浏览型号ESTW015A0F641-Z的Datasheet PDF文件第7页浏览型号ESTW015A0F641-Z的Datasheet PDF文件第8页浏览型号ESTW015A0F641-Z的Datasheet PDF文件第10页浏览型号ESTW015A0F641-Z的Datasheet PDF文件第11页浏览型号ESTW015A0F641-Z的Datasheet PDF文件第12页浏览型号ESTW015A0F641-Z的Datasheet PDF文件第13页  
Data Sheet  
ESTW015A0F Series Eighth-Brick Power Modules  
36–75Vdc Input; 3.3Vdc Output; 15A Output  
August 20, 2010  
Thermal Considerations  
The power modules operate in a variety of thermal  
environments; however, sufficient cooling should be  
provided to help ensure reliable operation.  
Please refer to the Application Note “Thermal  
Characterization Process For Open-Frame Board-  
Mounted Power Modules” for a detailed discussion of  
the thermal aspects including maximum device  
temperatures.  
Considerations include ambient temperature, airflow,  
module power dissipation, and the need for increased  
reliability. A reduction in the operating temperature of  
the module will result in an increase in reliability. The  
thermal data presented here is based on physical  
measurements taken in a wind tunnel.  
The thermal reference points, Trefx used in the  
specifications for open frame modules are shown in  
Figure 13. For reliable operation Tref1 and Tref2  
temperatures should not exceed 125oC and Tref3  
temperature should not exceed 110 oC.  
Figure 13. Tref Temperature Measurement  
Location for Open Frame Module.  
Heat Transfer via Convection  
Increased airflow over the module enhances the heat  
transfer via convection. Derating curves, showing the  
maximum output current that can be delivered by  
the module versus local ambient temperature (TA)  
for natural convection and up to 1m/s (200 ft./min)  
forced airflow, are shown in Figure 14. Full power up  
to TA=85 oC, is achieved for airflow of 1 m/s(200 LFM)  
or greater.  
16  
15  
NC  
14  
0.5m/s  
(100LFM)  
13  
1.0m/s  
(200LFM)  
12  
11  
10  
20  
30  
40  
50  
60  
70  
80  
90  
AMBIENT TEMEPERATURE, TA (oC)  
Figure 14. Output Current Derating for the Open  
Frame Module; Airflow in the Transverse Direction  
from Vout(+) to Vout(-); Vin =48V.  
LINEAGE POWER  
9