Data Sheet
March 19, 2009
EUE Series DC-DC Power Modules:
42-55/42-58Vdc Input; 12Vdc Output; 200/120W
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Input Voltage
Continuous
Non-Operating Condition
Operating Ambient Temperature
(see Thermal Considerations section)
Storage Temperature
I/O Isolation (100% factory Hi-Pot tested)
All
All
T
stg
-40
100
2250
°C
Vdc
EUE200
EUE120
All
All
T
A
V
IN
V
IN
-0.3
-0.3
-0.3
-40
55
58
75
85
Vdc
Vdc
Vdc
°C
Device
Symbol
Min
Max
Unit
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Operating Input Voltage
Maximum Input Current
(EUE200:V
IN
=0 to 55V , P
o
= 200W
, max
)
(EUE120:V
IN
=0 to 58V , P
o
= 120W
, max
)
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance; V
IN
=0
to 55V, P
o
= 200W
, max
;See Figure 17)
Input Ripple Rejection (120Hz)
EUE200
EUE120
All
All
All
I
IN,max
I
IN,max
It
2
Device
EUE200
EUE120
Symbol
V
IN
V
IN
Min
42
42
Typ
48
48
Max
55
58
Unit
Vdc
Vdc
Adc
Adc
As
mAp-p
dB
2
5
12.3
5.6
3.5
1
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being
part of complex power architecture. To preserve maximum flexibility, internal fusing is not included; however, to
achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-
acting fuse with a maximum rating of 10A (see Safety Considerations section). Based on the information provided in
this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be
used. Refer to the fuse manufacturer’s data sheet for further information.
LINEAGE
POWER
2