Data Sheet  
KW010/015/020/025 Series Power Modules:  
March 26, 2008  
36 – 75Vdc Input; 1.2 to 5.0Vdc Output; 10 to 25A Output current  
Feature Descriptions (continued)  
EMC Considerations  
The KW series modules are designed to meet the  
conducted emission limits of EN55022 class A with no  
filter at the input of the module. The module shall  
also meet limits of EN55022 Class B with a  
recommended single stage filter. Please contact your  
Lineage Power Sales Representitive for further  
information.  
The voltage between the Vo(+) and Vo(–) terminals  
must not exceed the minimum output overvoltage  
protection value shown in the Feature Specifications  
table. This limit includes any increase in voltage due  
to remote-sense compensation and output voltage  
set-point adjustment trim.  
Although the output voltage can be increased by both  
the remote sense and by the trim, the maximum  
increase for the output voltage is not the sum of both.  
The maximum increase is the larger of either the  
remote sense or the trim. The amount of power  
delivered by the module is defined as the voltage at  
the output terminals multiplied by the output current.  
When using remote sense and trim, the output  
voltage of the module can be increased, which at the  
same output current would increase the power output  
of the module. Care should be taken to ensure that  
the maximum output power of the module remains at  
or below the maximum rated power (Maximum rated  
power = Vo,set x Io,max).  
Level [dBµV]  
80  
70  
60  
50  
40  
30  
20  
10  
0
150k  
300k  
500k  
1M  
2M  
3M  
5M  
7M  
10M  
30M  
Frequency [Hz]  
MES CE0921041009_pre PK  
LIM EN 55022A V QP Voltage QP Limit  
Figure 44. KW015A0F Quasi Peak Conducted  
Emissions with EN 55022 Class A limits, no  
external filter (VIN = VIN,NOM, Io = 0.85 Io,max).  
Thermal Considerations  
The power modules operate in a variety of thermal  
environments; however, sufficient cooling should be  
provided to help ensure reliable operation.  
Level [dBµV]  
80  
Considerations include ambient temperature, airflow,  
module power dissipation, and the need for increased  
reliability. A reduction in the operating temperature of  
the module will result in an increase in reliability. The  
thermal data presented here is based on physical  
measurements taken in a wind tunnel.  
70  
+
60  
50  
40  
30  
20  
10  
0
The thermal reference point, Tref used in the  
specifications is shown in Figure 43. For reliable  
operation this temperature should not exceed 120oC.  
150k  
300k  
500k  
1M  
2M  
3M  
5M  
7M  
10M  
30M  
Frequency [Hz]  
+
MES CE0921041009_fin AV  
MES CE0921041009_pre AV  
LIM EN 55022A V AV  
Voltage AV Limit  
Figure 45. KW015A0F Average Conducted  
Emissions with EN 55022 Class A limits, no  
external filter (VIN = VIN,NOM, Io = 0.85 Io,max).  
Figure 43. Tref Temperature Measurement  
Locations.  
Please refer to the Application Note “Thermal  
Characterization Process For Open-Frame Board-  
Mounted Power Modules” for a detailed discussion of  
thermal aspects including maximum device  
temperatures.  
LINEAGE POWER  
15