Data Sheet
March 26, 2008
KW010/015/020/025 Series Power Modules:
36 – 75Vdc Input; 1.2 to 5.0Vdc Output; 10 to 25A Output current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Input Voltage
Continuous
Transient (100 ms)
Operating Ambient Temperature
(see Thermal Considerations section)
Storage Temperature
I/O Isolation voltage (100% Factory Hi-Pot tested)
All
All
T
stg
-55
125
1500
°C
Vdc
All
All
All
V
IN
V
IN,trans
T
A
-0.3
-0.3
-40
80
100
85
Vdc
Vdc
°C
Device
Symbol
Min
Max
Unit
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Operating Input Voltage
Maximum Input Current
(V
IN
= V
IN, min
to V
IN, max
, I
O
=I
O, max
)
Input No Load Current
(V
IN
= V
IN, nom
, I
O
= 0, module enabled)
Input Stand-by Current
(V
IN
= V
IN, nom
, module disabled)
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V
IN, min
to
V
IN, max,
I
O
= I
Omax
; See Test configuration section)
Input Ripple Rejection (120Hz)
EMC, EN55022
All
It
2
Device
All
All
All
Symbol
V
IN
I
IN,max
I
IN,No load
Min
36
Typ
48
1.7
55
Max
75
2.0
Unit
V
dc
A
dc
mA
All
I
IN,stand-by
5
7
mA
0.1
As
2
All
30
mA
p-p
All
50
60
100
dB
See EMC Considerations section
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included,
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies
require a time-delay fuse with a maximum rating of 5 A (see Safety Considerations section). Based on the
information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a
lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.
LINEAGE