欢迎访问ic37.com |
会员登录 免费注册
发布采购

MDX040A0X4-SR-P-HZ 参数 Datasheet PDF下载

MDX040A0X4-SR-P-HZ图片预览
型号: MDX040A0X4-SR-P-HZ
PDF下载: 下载PDF文件 查看货源
内容描述: 40A模拟兆丰DLynxTM : [40A Analog Mega DLynxTM:]
分类和应用:
文件页数/大小: 14 页 / 467 K
品牌: LINEAGEPOWER [ LINEAGE POWER CORPORATION ]
 浏览型号MDX040A0X4-SR-P-HZ的Datasheet PDF文件第3页浏览型号MDX040A0X4-SR-P-HZ的Datasheet PDF文件第4页浏览型号MDX040A0X4-SR-P-HZ的Datasheet PDF文件第5页浏览型号MDX040A0X4-SR-P-HZ的Datasheet PDF文件第6页浏览型号MDX040A0X4-SR-P-HZ的Datasheet PDF文件第8页浏览型号MDX040A0X4-SR-P-HZ的Datasheet PDF文件第9页浏览型号MDX040A0X4-SR-P-HZ的Datasheet PDF文件第10页浏览型号MDX040A0X4-SR-P-HZ的Datasheet PDF文件第11页  
Advance Data Sheet
November 17, 2011
40A Analog Mega DLynx
TM
: Non-isolated DC-DC Power Module
4.5 – 14.4Vdc input; 0.6Vdc to 2Vdc output; 40A output current
Feature Descriptions
Remote On/Off
The 40A Analog Mega DLynx power modules
feature an On/Off pin for remote On/Off operation.
Two On/Off logic options are available. In the Positive
Logic On/Off option, (device code suffix “4” – see
Ordering Information), the module turns ON during a
logic High on the On/Off pin and turns OFF during a
logic Low. With the Negative Logic On/Off option, (no
device code suffix, see Ordering Information), the
module turns OFF during logic High and ON during
logic Low. The On/Off signal should be always
referenced to ground. For either On/Off logic option,
leaving the On/Off pin disconnected will turn the
module ON when input voltage is present.
TM
Caution
– Do not connect SIG_GND to GND
elsewhere in the layout
Figure 3. Circuit configuration for programming
output voltage using an external resistor.
Table 1
V
O, set
(V)
0.6
0.9
1.0
1.2
1.5
1.8
Rtrim (KΩ)
Open
40
30
20
13.33
10
Remote Sense
The power module has a Remote Sense feature to
minimize the effects of distribution losses by regulating
the voltage at the SENSE pin. The voltage between
the SENSE pin and VOUT pin should not exceed 0.5V.
Monotonic Start-up and Shutdown
The module has monotonic start-up and shutdown
behavior for any combination of rated input voltage,
output current and operating temperature range.
Voltage Margining
Output voltage margining can be implemented in the
module by connecting a resistor, R
margin-up
, from the
Trim pin to the ground pin for margining-up the output
voltage and by connecting a resistor, R
margin-down
, from
the Trim pin to output pin for margining-down. Figure
4 shows the circuit configuration for output voltage
margining
Vo
Rmargin-down
Startup into Pre-biased Output
The module can start into a prebiased output as long
as the prebias voltage is 0.5V less than the set output
voltage.
Output Voltage Programming
The output voltage of the module is programmable to
any voltage from 0.6dc to 2Vdc by connecting a
resistor between the Trim and SIG_GND pins of the
module. Without an external resistor between Trim and
SIG_GND pins, the output of the module will be
0.6Vdc. To calculate the value of the trim resistor,
Rtrim
for a desired output voltage, should be as per
the following equation:
MODULE
Q2
Trim
Rmargin-up
Rtrim
12
Rtrim
=
k
Ω
(
Vo
0.6
)
Rtrim is the external resistor in kΩ
Vo
is the desired output voltage. Table 1 provides
Rtrim values required for some common output
voltages.
V
IN
(+)
V
O
(+)
VS+
ON/OFF
TRIM
R
trim
SIG_GND
VS─
LOAD
SIG_GND
Q1
Figure 4. Circuit Configuration for margining
Output voltage.
Output Voltage Sequencing
The power module includes a sequencing feature, EZ-
SEQUENCE that enables users to implement various
types of output voltage sequencing in their
applications. This is accomplished via an additional
sequencing pin. When not using the sequencing
feature, leave it unconnected.
The voltage applied to the SEQ pin should be scaled
down by the same ratio as used to scale the output
voltage down to the reference voltage of the module.
This is accomplished by an external resistive divider
LINEAGE
POWER
7