NH020-Series Power SIPs:  
5 Vdc Input; 1.5 Vdc to 3.3 Vdc Output; 20 W  
Data Sheet  
October 14, 2009  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress  
ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the  
operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the  
device reliabiltiy.  
Parameter  
Symbol  
Min  
Max  
Unit  
Input Voltage:  
Continuous  
VIN  
TQ31  
0
–40/0†  
–55  
7.0  
115  
125  
6.0  
Vdc  
°C  
Operating Ambient Temperature*  
Storage Temperature  
Tstg  
°C  
On/Off Terminal Voltage  
Von/off  
Vdc  
* Forced convection—1.5 ms–1 (300 lfm) minimum. Higher ambient temperatures are possible with increased airflow and/or decreased power  
output. See the Thermal Considerations section for more details.  
† The –40 °C operation is optional. See Ordering Information section.  
Electrical Specifications  
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.  
Parameter  
Symbol  
VI  
Min  
4.5  
Typ  
Max  
5.5  
Unit  
Vdc  
A
Operating Input Voltage  
Maximum Input Current  
(VI = 0 to VI,max; IO = IO,max)  
5.0  
II,max  
6.1  
Inrush Transient  
i2t  
1
A2s  
Input Reflected-Ripple Current  
625  
mAp-p  
(5 Hz to 20 MHz; 500nH source impedance;See Figure 14)  
Input Ripple Rejection  
(100 - 120Hz)  
60  
dB  
CAUTION: This power module is not internally fused. An input line fuse must always be used.  
This power SIP can be used in a wide variety of applications, ranging from simple stand-alone operation to an  
integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included; however,  
to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a normal-blow  
fuse with a maximum rating of 10 A (see Safety Considerations section). To aid in the proper fuse selection for the given appli-  
cation, information on inrush energy and maximum dc input current is provided. Refer to the fuse manufacturer’s data for fur-  
ther information.  
Lineage Power  
2